Technical description
5
Technical description
The ozone generator purifies the air and removes bacteria, viruses, spores,
mould, fungi and harmful chemical substances. A fan draws oxygen into the
ozone generator for this purpose.
Corona discharge (500 mg/h) produces ozone, which is distributed by the
internal fan. The ozone removes odours by breaking down the molecules
responsible for the odours in chemical reactions, and germs and bacteria are
then deactivated because their DNA is destroyed.
After approx. 20 minutes, the ozone breaks down into oxygen again.
The device is operated with 12 Vg.
5.1
Operating and display elements
No. in
fig. 1,
Description
page 3
1
START/STOP
2
15'
3
30'
4
45'
5
60'
16
Explanation
This button switches the ozone generator on and
off.
The 15 min-LED indicates that ozone flows out for
15 minutes.
The 30 min-LED indicates that ozone flows out for
30 minutes.
The 45 min-LED indicates that ozone flows out for
45 minutes.
The 60 min-LED indicates that ozone flows out for
60 minutes.
OZ500
EN