Página 1
Certificate • Certificat • Certificado • Zertifikat • Certificato CERTIFICATE OF COMPLIANCE We hereby certify that the device User Manual PoolLab 1.0 Manuel d’utilisation With it‘s serial number as stated below, has passed intensive visual and technical Manual de usuario checks as part of our QM documentation.
Página 2
Delivery content • Contenu du colis • Contenido de la entrega • Lieferumfang • CONTENT contenuto della confezione PoolLab 1.0 Delivery content Light shield Changing Batteries AAA Batteries Switch on/off Crushing / Stirring Rods General Advices 6 - 7 10ml syringe ZERO 8 - 9 User guide...
Página 3
Batteries • Piles • Pilas • Switch on • Allumer • Encender • Batterien • Batterie Einschalten • Accendere Change • chargement • cambio • wechseln • cambiamento 2 sec. · ZERO On/Off button can also be used to skip countdown during measurement (not recommended) Le bouton Marche / Arrêt peut être également utilisé...
Página 4
Advices • Conseils • Consejos • IMPORTANT • IMPORTANTE • WICHTIG • Hinweise • Consigli Always use PHOTOMETER grade tablets! Never use RAPID grade tablets! Do not touch reagent tablets! Detergent waterproof Toujours utiliser des pastilles (IP68 ) de qualité PHOTOMETRE! Ne jamais utiliser des pastilles de ZERO qualité...
Página 5
ZERO Only 1 time per test batch • Une seule fois par lot de 3 x = test • Sólo una vez por lote de prueba • Nur 1 x pro waterproof Testreihe • solo una volta per test in batch (IP68 ) ZERO Once you performed ZERO, all measurements, like pH, chlorine...
Página 6
After / Après / Después de / Nach / Dopo ZERO completely Phenol Red dissolved Photometer Range: 6.50 - 8.40 pH Reagent: Phenol Red Photometer TEST! TEST! residue ZERO ZERO 3 x = waterproof (IP68 ) ZERO 10 ml 15 sec. 7.10 waterproof TEST!
Página 7
Chlorine After / Après / Después de / Nach / Dopo ZERO Free Chlorine • Chlore libre • Cloro libre • Chlore Freies Chlor • Cloro libero N° 1 Cloro Photometer completely Chlor dissolved Cloro Range: 0.00 - 6.00 mg/l (ppm) Reagents: DPD N°...
Página 8
Total Chlorine • Chlore total • Cloro total • Gesamt-Chlor • Cloro totale Total Chlorine is measured directly after free Chlorine N° 3 without emptying the cuvette. The DPD 3 tablet is added Photometer to the sample water which already contains the DPD 1 tablet (dissolved).
Página 9
After / Après / Después de / Nach / Dopo ZERO Cyanuric Acid Cyan. Acid • Acide Cyan • Ácido Cian. • Cyanursäure • Acido Cianurico Acide cyanurique CYA-Test Ácido cianúrico completely Photometer dissolved Cyanursäure Acido Cianurico Range: 0 - 160 mg/l (ppm) TEST! TEST! Reagent:...
Página 10
After / Après / Después de / Nach / Dopo ZERO Alkalinity Alkalinity • Alcalinité • Alcalinidad • Alcalinité Alkalinität • Alcalinità Alkalinity-M Alcalinidad Photometer Alkalinität completely dissolved Alcalinità Range: 0 - 300 mg/l (ppm) CaCO TEST! TEST! Reagent: Alkalinity-M Photometer ZERO ZERO 3 x =...
Página 11
After / Après / Después de / Nach / Dopo ZERO Active Oxygen (MPS) Active Oxygen • Oxygène actif • Oxígeno activo Aktivsauerstoff • Ossigeno Attivo Oxygène actif (MPS) N° 4 Oxígeno activo (MPS) Photometer* Aktivsauerstoff (MPS) completely dissolved Ossigeno Attivo (MPS) Range: 0.3 - 30.0 mg/l (ppm) TEST!
Página 12
After / Après / Después de / Nach / Dopo ZERO Chlorine Dioxide Cl.Dioxide • Dioxyde de Cl • Dióxido de Cl Dioxyde de Chlore Chlordioxid • Biossido di Cl Dióxido de cloro Only if your water sample does contain Chlorine next to Chlorine Chlordioxid Dioxide (both disinfectants used), the following procedure „A“...
Página 13
After / Après / Después de / Nach / Dopo ZERO After / Après / Después de / Nach / Dopo ZERO Cl.Dioxide • Dioxyde de Cl • Dióxido de Cl Cl.Dioxide • Dioxyde de Cl • Dióxido de Cl Chlordioxid •...
Página 14
After / Après / Después de / Nach / Dopo ZERO Bromine Bromine • Brome • Bromo • Brome Brom • Bromo Bromo Brom Only if your water sample does contain Chlorine next to Bromine (both disinfectants used), the following procedure „A“ needs to be Bromo followed and Glycine reagent needs to be used.
Página 15
After / Après / Después de / Nach / Dopo ZERO After / Après / Después de / Nach / Dopo ZERO Bromine • Brome • Bromo • Bromine • Brome • Bromo • Brom • Bromo Brom • Bromo With Chlorine / Avec du Chlore / Con Cloro / Without Chlorine / Sans Chlore / Sin Cloro / Mit Chlor / Con il Cloro...
Página 16
After / Après / Después de / Nach / Dopo ZERO Ozone Ozone • Ozono • Ozon Ozono Ozon Only if your water sample does contain Ozone next to Chlorine Dioxide (both disinfectants used), the following procedure „A“ needs to be followed and Glycine reagent needs to be used. Range: 0.0 - 4.0 mg/l (ppm) Otherwise (only Ozone present), please follow procedure...
Página 17
After / Après / Después de / Nach / Dopo ZERO After / Après / Después de / Nach / Dopo ZERO Ozone • Ozono • Ozon Ozone • Ozono • Ozon With Chlorine / Avec du Chlore / Con Cloro / Without Chlorine / Sans Chlore / Sin Cloro / Mit Chlor / Con il Cloro Ohne Chlor / Senza Cloro...
Página 18
After / Après / Después de / Nach / Dopo ZERO Hydrogen Peroxide Hyd. Perox. • Perox. d‘hyd. • Peróx. de Hidr. Peroxyde d'Hydrogène Wasserstoffperox. • Peross. di Idrog. Hyd. Peroxide LR Peróxido de Hidrógeno Photometer* Wasserstoffperoxid completely dissolved Perossido di Idrogeno Range: 0.3 - 2.9 mg/l (ppm) TEST!
Página 19
After / Après / Después de / Nach / Dopo ZERO Total Hardness Total Hardn. • Dureté Totale • Dureza Total Dureté Totale Gesamthärte • Durezza Totale POL20TH1* Dureza Total POL10TH2* Gesamthärte Durezza Totale 10 x Range: 0 - 500 mg/l (ppm) CaCO TEST! TEST! Reagent:...
Página 20
After / Après / Después de / Nach / Dopo ZERO Calcium Hardness Total Hardn. • Dureté Totale • Dureza Total Dureté Calcique Gesamthärte • Durezza Totale Calcium Hardn. N°1* Dureza de Calcio Calcium Hardn. N°2* Kalziumhärte completely dissolved N°1 N°2 Durezza del Calcio Range:...
Página 21
Error codes • Codes d'erreur • OR-UR / Dilution • OR-UR / Verdünnung • Códigos de error • Fehlercodes • OR-UR / Dilución • OR-UR / Diluzione codici di errore OR = Overrange / UR = underrange. Test result is outside the range of the method.
Página 22
Changing the cuvette • Changer la cuvette Cambiar la cubeta • Küvettenwechsel Accessories • Accessoires • Accesorios • cambiando la cuvetta Zubehör • Accessori Reagents • Réactifs • Reactivos • Reagenzien • Reagenti 90° POL01-Nf 20/20/10/10/10 Phenol Red / DPD N° 1 / DPD N°...
Disposal CE compliance statement Batteries We, the manufacturer of the PoolLab 1.0 Photometer hereby According to EC Guideline 2006/66/EC, user is obliged to dispose declare comliance of PoolLab 1.0 Photometer with the essential in a proper manner by returning worn out batteries to dedicated requirements in accordance to the Directive 2014/53/UE of the collection places such as any shop selling batteries.
Página 25
GmbH could void the user‘s authority to operate the equipment. help. FCC ID: 2ALRR-POOLLAB10 Industry Canada Licence-Exempt Radio Apparatus 22610- POOLLAB10 This device complies with Industry Canada licence-exempt RSS Model: POOL LAB 1.0 standard(s). Operation is subject to the following two conditions:...