Options for Working with the Measured Values
Acknowledgement of the measured values: For the use of the indi-
vidual measured values in an application software, the type of acknowl-
edgement can be defined.
–
Manual acknowledgement: With manual acknowledgement, the
measured value is overwritten on the PC or PDA until it is manually ac-
knowledged (e.g. by pressing the arrow buttons). In this manner, a
measurement can be repeated until the correct (desired) measured
value is present.
–
Automatic acknowledgement: With automatic acknowledgement,
a return ("Enter") is automatically inserted after each measured value.
This option makes possible that, for example in Microsoft
data of several measurements can be written consecutively in a col-
umn without having to separately acknowledge each measured value.
Selection of the measuring unit: The measured values can be dis-
played in the measuring units of m, cm or mm.
Selection of the decimal point: As the decimal point for the display of
the measured values, a coma ("##,###", e.g. 23,35 m) or a period
("##.###", e.g. 23.35 m) can be selected.
Measurement Functions
Length Measurements
Press the length measuring button
measurements. The symbol for length measurements appears in the up-
per part of the display.
Area Measurement
Press the area measuring button
measuring. The symbol for area measurements appears in the upper part
of the display.
1 609 929 F53 • (04.07) T
In the "Options" menu of the "BOSCH DLE
150" software, the format of the displayed
measured values as well as the type of their
acknowledgement can be defined. In this
manner, the format for the display of the
measured values in the Software is defined
but the display on the DLE 150 Connect re-
mains unchanged.
For the selection of the options, click on the
respective menu item. The current selection
is marked in the menu with a check mark.
2 to switch to the mode for length
To measure, press the measure button 7
completely down.
The measured value is shown at the bottom of
the display and transmitted automatically at
the same time.
5 to switch to the mode for area
Then measure the length and width one after
the other as for a length measurement. The
individual values are transmitted automatical-
ly. After completion of the second measure-
ment, the result is automatically calculated
and displayed but not transmitted.
The individual measured values are shown in
the upper right of the display, the results at the
bottom.
English–12
®