Putting into Operation

Switching On/Off
Switching on:
Press the "on/off" button 6 or the measurement button 7 completely
down.
Switching off:
Press the "on/off" button 6.
After approx. 10 min without performing a measurement, the unit switch-
es off automatically to save the batteries.
When automatically switched off, the current display and the settings of
the DLE 150 Connect are also stored in addition to the measured values.
However, an existing wireless connection is interrupted (see Sections In-
stalling the "BOSCH DLE 150" Software and Starting the "BOSCH DLE
150" Software).
When switched on again, the DLE 150 Connect is in the same functional
mode and shows the same display as before the automatic switch-off. To
re-establish the wireless connection between the DLE 150 Connect and
the PC or PDA, see Section Wireless Connection.
Measuring Procedure
The instrument has several measuring functions that can be selected by
pressing the respective function button (see Measurement Functions
Section). After switching on, the instrument is in the "Length Measuring"
function.
To change the measuring function, press the button for the desired func-
tion. After selecting the measuring function, all further steps take place by
pressing the measure button 7.
Place the rear end of the unit (end piece) at the desired measuring position
(e.g. on a wall). The rear end of the unit is the reference point for the
measurement.
To switch on the laser beam, lightly press the measurement button 7
in the middle or press at the side.
Aim at the target.
Do not point the laser beam at persons or animals and do not
s
look into the laser bean, even from longer distances.
To measure, press the measure button 7 completely down.
The measured value appears after 0.5 to 4 s. The end of the measure-
ment is indicated by an acoustical signal. The duration of the measure-
ment is dependent on the distance, light conditions and reflection charac-
teristics of the measured surface. After completion of the measuring
procedure, the laser switches off automatically.
If a wireless connection exists to a PC or PDA, the last measured individ-
ual value is automatically transmitted after each measurement to the PC
or PDA (see Section Working with the "BOSCH DLE 150" Software).
Continuous Pointer Mode
The unit can be switched to continuous laser beam (continuous pointer
mode) as required. For this purpose, press the somewhat recessed con-
tinuous pointer mode button
switched on between the measurements in this setting. For measuring,
only a single complete pressing down of the measurement button 7 is
necessary.
1 609 929 F53 • (04.07) T
10. The laser beam will also remain
English–5

Publicidad