1. Remove the plug
from the power sock-
et.
2. Tilt back the appli-
ance carefully so that
the compressor can-
not touch the floor.
3. Unscrew the left
foot.
4. Unscrew the
screws of the door
bottom hinge. Remove
the hinge. Put over the
pin in the direction of
the arrow.
5. Unscrew and install
the screw on the op-
posite side.
6. Install the hinge on
the opposite side.
7. Screw the right
foot.
1) If foreseen
Do a final check to make sure that:
• All screws are tightened.
• The door opens and closes correctly.
If the ambient temperature is cold (i.e. in Win-
ter), the gasket may not fit perfectly to the cabi-
net. In that case, wait for the natural fitting of
the gasket.
In case you do not want to carry out the above
mentioned operations, contact the nearest After
Sales Service Force. The After Sales Service
specialist will carry out the reversibility of the
doors at your cost.
20
8. Unscrew both
screws on the rear
side.
9. Push back the top
and lift it from the fix-
ing elements.
10. Unscrew the
screws of the door top
hinge.
11. Remove the hinge.
Put over the pin in the
direction of the arrow.
Install the hinge on the
opposite side.
12. Tighten the hinge.
13. Put the top in po-
sition.
14. Pull it forward.
15. Screw both
screws on the rear
side.
Electrical connection
Before plugging in, ensure that the voltage and
frequency shown on the rating plate corre-
spond to your domestic power supply.
The appliance must be earthed. The power
supply cable plug is provided with a contact for
this purpose. If the domestic power supply
socket is not earthed, connect the appliance to
a separate earth in compliance with current
regulations, consulting a qualified electrician.
The manufacturer declines all responsibility if
the above safety precautions are not observed.
This appliance complies with the E.E.C. Direc-
tives.
16. Remove and install
1)
the handle
on the
opposite side.
17. Reposition, level
the appliance, wait for
at least four hours and
then connect it to the
power socket.
www.zanussi.com