Dr90 Specifications - Honeywell TrueDRY DR90 Serie Guia De Instalacion

Ocultar thumbs Ver también para TrueDRY DR90 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

DR90 Specifications
Install TrueDRY DR90 according to National Electric Codes.
Dry-Bulb Temp
80°F (26.7°C)
70°F (21.1°C)
60°F (15.6°C)
Home Size
(square ft [m])
2080 (193.2)
2600 (241.5)
3120 (289.9)
* Based on extreme climates where outdoor humidity is 70-90% RH. For less extreme climates, larger
homes can be adequately served with less capacity. Actual requirements may vary.
Dimensions in inches and (mm):
14-3/8
(365)
19-3/8
(492)
Product weight: 82 lbs.
Shipping weight: 93 lbs.
Shipping dimensions: 21.5"H x 18.5"W x 40.0"L
Media Filter: MERV 11, 14"H x 18"W x 2"L
Drain connection: 3/4-in. threaded female NPT connection.
Duct connections: 10-in. round inlet and outlet. 6-in. supply
inlet. ABS plastic, compatible for connection to rigid or
flexible ducting with sheet metal screws and/or tape.
Cabinet: 20 ga
Insulation: R value 1
Compressor: Rotary, 8.0k BTu
Refrigerant: R-410A, 21 oz
Operating Temp Range (outside cabinet):
34ºF to 135ºF (1.1ºC to 57.2ºC)
Operating Humidity Range: 0-99% RH
4
Intake Humidity
Capacity (Pints/Day)
60% RH
60% RH
60% RH
Dehumidifier Capacity Required to Maintain Desired Indoor RH*
60% RH Indoor
(pints/day)
49–54
61–68
75–82
3-3/16
25-13/16
(81)
(656)
90
73
54
50% RH Indoor
(pints/day)
55–58
65–72
79–86
Airflow versus external static pres-
sure (0–1 in. [0 - 25.4 mm] water
3-3/16
(81)
pressure) with collars attached
0 in. (0 mm)
0.2 in. (5 mm)
0.4 in. (10 mm)
0.6 in. (15.2 mm)
M28840A
Input ratings
• Electrical input voltage: 120 VAC,
• Input current: 5.9 A
Output ratings
• Power transformer to R/C
• Energy Performance: 2.9 liters (6.1
Standards and approval body
requirements
ETL Tested per standard uL 474 ducted
dehumidifier.
ENERGY STAR rated.
TrueDry DR90/DR120 Dehumidification System 69-2690EFS—04
40% RH Indoor
(pints/day)
71–78
90–97
95–110
262 CFM
225 CFM
172 CFM
106 CFM
60 Hz nominal
terminals: 24 VAC, 0.85 A
pints) per kilowatt hour (KWH)

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Truedry dr120 serieTruedry dr120a2000/uTruedry dr90a2000/uTruedry dr90Truedry dr120

Tabla de contenido