EdilKamin ECOIDRO Guía De Instalación, Uso Y Mantenimiento página 40

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

FAQ
The answers shown here summarize the information found in these specifications.
1) What fittings do I need in order to install Ecoidro?
Smoke outlet of at least 80 mm in diameter.
Air intake in the room of at least 80 cm2.
¾" G manifold outlet and inlet.
¾" G outlet to drain for overpressure valve.
Coupling for ¾" G filling line.
Connection to an electrical system compliant with standards, with a 230 V +/- 10% 50 Hz thermal-magnetic circuit breaker.
Refer to page 24 for dimensions. Read the installation safety information on page 27.
2) Can I use the stove without water?
NO. Use without water damages the stove.
3) Does the Ecoidro stove give out hot air?
NO. All the heat goes where it is needed: to the water. Part of the heat produced is radiated into the room. You are advised to fit
heat emitting units (radiators) in the room.
4) Can I connect the stove inlet and outlet directly to a heat emitting unit (radiator)?
NO, like all other water heaters, they must be connected to a manifold from which the water is distributed to the heat emitting
units.
5) Does the Ecoidro stove also provide domestic hot water?
It may be produced using our kit IDROKIT or produced and stored by water heaters (see plumbing diagrams on page 28).
6) Can the Ecoidro smoke outlet pass directly through the wall?
NO, an outlet installed in a workmanlike manner (Italian standard UNI 10683/05) is on the roof ridge. In any case, there must be
a vertical section of at least 1.5 metres for correct operation. Otherwise, a small amount of smoke may be perceived in the room
in the event of power failure or wind.
7) Does there have to be an air intake in the room?
Yes, to replenish the air in the room. There is no direct connection between the air intake and the stove: the smoke extractor
draws air from the room and supplies it to the combustion chamber.
8) What is the temperature of the smoke emitted?
It leaves at a maximum of 140°C if the system has the correct dimensions and the pellets are good quality.
9) What do I have to set on the stove display?
The water temperature required: the stove modulates the power on the basis of this setting to attain or maintain it. For small
systems, the stove may be programmed to turn on and off according to the water temperature reached.
10) How often do I have to clean the combustion chamber?
Ideally before each stove ignition, while cold before turning it on. Clean the chamber AFTER CLEANING THE HEAT
EXCHANGE PIPES WITH THE BRUSHES and operating the smoke duct cleaning rods.
11) Should I vacuum-clean the pellet hopper?
Yes, at least once a month or if the stove has not been used for a long time.
12) Can I burn other things apart from pellets?
NO. The stove is designed to burn 6 mm pellets. Other materials may damage it.
13) Can I turn the stove on with a mobile phone text message?
Yes, if the Dealer or an electrician has fitted a dialler to the electronic circuit board AUX port.