Descargar Imprimir esta página

Technical Characteristics; Leak Check - Coleman 5431B Serie Instrucciones De Uso

Estufas de gas propano
Ocultar thumbs Ver también para 5431B Serie:

Publicidad

Idiomas disponibles

Idiomas disponibles

Technical
Characteristics
Input: 10,000 BTU/H per burner
Category: Pressure regulated propane
Fuel: 16.4 oz. disposable propane cylinders
Regulator: 5431
To Set Up
DANGER
• CARBON MONOXIDE HAZARD
• For outdoor use only.
• Never use inside house, camper, tent, vehicle
or other unventilated or enclosed areas. This
stove consumes air (oxygen). Do not use
in unventilated or enclosed areas to avoid
endangering your life.
• NOTE: Use Coleman
propane cylinders. The LP-gas cylinder(s)
used with stoves must be constructed and
marked in accordance with the specifications
for LP-gas cylinders of the U.S. Department of
Transportation or Transport Canada, CAN/CSA
B339.
• Turn FUEL VALVE "off". (Fig. 1)
CAUTION
• SERVICE SAFETY
• Keep all connections and fittings clean.
Inspect propane cylinder and stove propane
connections for damage before attaching.
• During set up, check all connections and
fittings for leaks using soapy water. Bubbles
indicate a leak. Never use a flame.
• Remove protective cap from top of propane
cylinder. Save cap for use in storing.
• Screw propane cylinder into stove. Take care not
to cross thread. HAND TIGHTEN only. (Fig. 2)
16.4 oz. disposable
®
• Place cylinder securely in stove base. (Fig. 3)
Fig. 1

Leak Check

• Perform leak test outdoors.
• Extinguish all open flames.
• NEVER leak test when smoking.
• Do not use the outdoor stove until connec-
tion has been leak tested and does not leak.
English-3
WARNING
Fig. 2
Fig. 3

Publicidad

loading