Page 10
To prevent risk of fire which could result in property damage,
and to ensure optimum performance, do not exceed the load
factor specified in the instructions provided by the transformer
manufacturer
.
White - Neutral
Black - Hot (Line)
Figure 5.
Wiring LED Lights to a 12 Volt Transformer
NOTE A dimmer switch or dimming relay may be used when Jandy Pro
Series Nicheless WHITE ONLY lights are installed. Jandy Pro
Series color lights are NOT DIMMABLE and are NOT COMPATIBLE
with dimmer switches or dimmer relays.
Section 4.
Underwater LED Light Operating Instructions
4.1
Light Synchronization
NOTE This section only applies to the color (RGBW) lights. All fixtures
must be tied into the same transformer, circuit or switch for
synchronization to occur.
1. Turn the light ON. If the light has been off for 7 seconds or longer, the
light will turn on at the last color selected.
2. To synchronize multiple lights to the same color mode, you will need to
reset to the beginning of the color mode sequence. With the lights ON,
turn them OFF for five (5) seconds, then turn ON again. All of the lights
will reset to the Alpine White color mode. If all of the lights are not in
the Alpine White color mode, they have not been synchronized, repeat
step 2.
ENGLISH
CAUTION
Time clock, Automation relay,
or switch
Jandy
Pro Series Nicheless
®
Nicheless Underwater LED Lights | Owner's Manual
Class 2 Transformer
Output: 12-14 VAC
Ground Bar