Installation
Instructions
ELECTRICAL REQUIREMENTS
Read
these
instructions
completely
and
carefully.
CIRCUIT
- Individual,
properly
polarized
and grounded
15-amp
branch
circuit fllsed with 15-amp time-delay
fllse
or circuit
breaker:
POWER
SUPPLY-
2-wire, with gro/md,
120wolt, single-
phase,
60-Hz, Mternating
CmTent.
OUTLET
RECEPTACLE
- Properly
grounded
3-prong
receptacle
to be locamd
so the power SUl)ply cord
is accessible
when the washer is in an installed
position.
@
@
GROUNDING
REQUIREMENTS
A WARNING:
connection
ofthe
equipment
g_x)tmding
conductor
can result in a risk
(ff electrical
shock. Check with a licensed
electrician
flyou are in doubt
as to whether
the appliance
is
propedy
gromMed.
1,
Tile washer MUST be grotmded.
In tile event oI
malflmction
or breakdown,
grounding
will reduce
the risk ()t electrical
shock by pr(Mding
a path of least
resistance
for electrical
cmTent.
Since v()m" washer is equipped
with a power supply
cord having an equipment-gromMing
conductor
and
a gromMing
plug, the plug MUST be plugged
into an
al)l)ropriate
, coppe_vired
receptacle
that is i)roperly
installed
and gro/mded
in accordance
with all local
codes and ordinances
or in the absence
ot local codes,
with the National
Electrical
Codes, ANSI/NFPA
70
(latest edition)./t
in doubt,
call a licensed
electfidan.
DO NOT
etlt off- or alter tile grotmding
prong
on tile
power suI)ply cord. In situations
where
a two-slot
receptacle
is present,
it is the owner's
responsibility
to
have a licensed
electrician
replace
it with a properly
grounded
three-prong
gromMing-Ql)e
receptacle.
WATER SUPPLY REQUIREMENTS
Hot and cold water fimcets MUST
be installed
within
42 inches
(] 07 cm) of yore" washer's
water inlet. The
fimcets MUST be 3/4"
(1.9 cm) garden
hose-t)'l)e so
inlet hoses can be connected.
Water
pressm'e
MUST be
bet_ven
10 and 120 pounds
per square inch
(maMmum
tmbalanced
pressm'e,
hot vs. cold, l 0 psi.) Yimr _;_ter
department
can a(Mse )'ou of yore" water pressure.
The hot water temperature
should
be set to deliver
water at 120 ° to 140°F (48°-(;0°(:).
DRAIN REQUIREMENTS
1. Drain
capable
ot eliminating
17 gals (64.3 i,)
per minute.
2. A standpipe
diameter
of 1 1/4"
(3.18 cm) minim urn.
3. Tile standpipe
height
above tile floor
should
be:
Minimum
height:
24" (61 cm)
Maxim umh eight: 96" (244 cm )
o
oo
J
_REAR
96"
(244cm)
Max.
NOTE: Tile drain hose am_ched
to tile washer can reach
a 90" (229 cm) high standpipe.
For a higher
standpipe,
contact
an authorized
parts distributor:
If tile drain is less
than 24" (61 cm), install a siphon
break
kit, available
at
yore" local hardware
store.
14