Service
Settings using the HyTronic Service Handy
Commands
Menu item
Description
[EN]
[DE]
20
Release flush.
[Flush]
Releases a flush
[Spülung]
21
Check detection range.
[RangeTest]
Red LED in the sensor window
[TestErfas]
starts to light up when an
object enters the detection
range, but no flush is released.
The function switches off
automatically after 10 min
22
Block flush.
[BlocFlush]
No flush is released. The LED
[Blockiere]
flashes twice every 6 s.
The function switches off
automatically after 10 h
23
Empty pipe.
[EmptyPipe]
The valve is opened so that the
[RohrLeer]
pipe can be drained. The LED
flashes twice every 6 s. The
function switches off
automatically after 30 min
24
Factory settings.
[FactrySet]
All functions are reset to the
[Werkseinst]
factory setting. LED flashes 3
times and a flush is released
25
Switch cleaning mode.
[CleanMode]
The LED flashes twice every
[Reinigung]
3 s. Flush control is inactive for
the duration of the entered
value 45 [CleanTime] [ReiniZeit].
Flushes at the end of this period
34
Orientation
The functions described below may only be set by a skilled person.
The functions for the HyTronic urinal flush control can be set individually using the
HyTronic Service Handy. The numbers and terms in the column "Menu item"
correspond to what can be seen on the display of the HyTronic Service Handy.
Further information can be found in the operating instructions for the HyTronic
Service Handy.
Application
a) Function test for the valve
b) Flushing of the urinal ceramic
(e.g. when setting the optimum
flush volume)
Problems with the user
detection
In the event of detection
malfunctions
a) For repair works and
maintenance work
b) Winter emptying
In the case of malfunctions
Cleaning the cover plate or the
urinal ceramic without flushing
Adjustment
Factory
range
setting
Start = "OK"
-
On = "OK"
Off = [OFF]
Off = "OK"
On = "OK"
-
Off = "OK"
On = "OK"
-
Off = "OK"
Start = "OK"
-
Start = "OK"