Error Messages During Operation - geberit HyTronic Instrucciones De Uso

Ocultar thumbs Ver también para HyTronic:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 53

Error messages during operation

Connection error
Error message
[E17 IR-Fehl]
[E19 Steuerng]
[E20 Sync]
[E21 KeinSign]
[E23 Type]
[E24 Schreibe]
[E25 S-Handy]
[E26 NoData]
Error message of the control
Error message
[E01 Bereich!]
[E02 zu Klein]
[E03 zu Gross]
[E04 BattTief]
[E05 BattLeer]
[E06 Ventil]
[E07 Aktor]
[E09 Code]
Other errors
Errors
Control does not work after
settings have been made.
HyTronic Service Handy, Bidirectional
During operation, error messages may be displayed. Remedy the problem with the
help of the table.
By pressing any button, the display returns from the error message back to the
original information.
Possible cause
Bad signal quality
Wrong or several controls are
addressed
Contact between HyTronic Service
Handy and control interrupted
Interference of an external signal
Wrong control is addressed
Internal error
HyTronic Service Handy is not aimed at
control
No signal received from control
Attempt to switch on working control
again
Memory type does not correspond to
control
Transmission failure during saving or
writing due to too bright ambient light or
interruption of the signal
Device failure
Wrong or no data when writing data on
control
Possible cause
Invalid value entered
Entered value is too low
Entered value is too high
Low battery capacity of the control
Battery of the control is empty
Valve cable is not plugged in
Valve cable has a loose contact
Servo cable is not plugged in
Flushing system is not put in the lever of
the servo
Servo cable has loose contact
Wrong code entered
Sensor turned off or faulty
Possible cause
Contact with control has not been
ended; control remains inactive for
10 minutes
Operation
Remedy
• Clean sensors of the HyTronic Service
Handy and of the control
• Aim HyTronic Service Handy at the
sensor of the control
• Establish contact anew
• Address right control
• Establish contact anew
• Aim HyTronic Service Handy at the
sensor of the control
• Establish contact anew
• Contact is already established
• Address right control
• Reduce ambient light
• Aim HyTronic Service Handy at the
sensor of the control
• Establish contact anew
• If failure occurs repeatedly, give device
to sales company
• Save data correctly
Remedy
• Enter correct value
• Enter value within the setting range.
For setting range, see operating
instructions of control
• Insert new batteries into control
• Establish contact anew
• Plug in valve cable correctly
• Change valve
• Plug in servo cable correctly
• Put flushing system in the lever of the
servo
• Change servo
• Enter right code
• Test or replace sensor
Remedy
• End contact
DE
EN
FR
IT
NL
ES
PT
DK
NO
SE
FI
IS
PL
HU
SK
CZ
SL
HR
SR
EE
LV
LT
BG
RO
GR
TR
RU
AE
CN
JP
21

Publicidad

Tabla de contenido
loading

Productos relacionados para geberit HyTronic

Tabla de contenido