EN
Function
The new T-serial swimming pool pump is the high-tech version of the
normal swimming pool pump. The new one has an included timer.
By adjusting the desired time (2,4,6,10,12,16 or 24 hours), the pump
will operate from this point in time for the adjusted time and stand
still for the rest of the 24 hours.
Within 24 hours, the filter run time can be adjusted only once. Ad-
justing several intervals within 24 hours is not possible.
The timer has a rechargeable battery
2032) included to save the settings in the case of a electrical power
outrage. If there will be an electrical power outrage the pump will
start automatically at the next day, if the electrical power is back.
The remaining time of the filter cycle is showed on the LED of the
pump.
Description (Illustration 1)
1 drain cap
2 pump body
3 screw M88*3r
4 inlet connector
5 outlet connector
6 timer
7 body cover
8 fix hole
9 base plate
Technical Specifications
For technical specifications please refer tot he type plate oft he filter
pump.
Before replacing
the
battery
the
pump must
always
be separat-‐
ed by
p ulling
o ut
t he mains
p lug from
t he
m ains!
Commissioning of the timer / battery
change
Use a screwdriver to tighten the
Open the cover
Gently press your finger to the side of the battery, this pops out
freely. Change the battery (lithium button cell 3V CR
tion 4)
WARNING-INITIAL:
The already built-in battery has a protective part (plastic strips) to
prevent premature discharge of the battery to. Before commissioning
it must be unlocked. If it can not be unlocked, the timer still works
flawlessly. However, be saved filter run times will be deleted in the
event of a power outage.
(Illustration 4A, 4B)
Close the cover.
Use a screwdriver to tighten the cap back on.
Timer Settings
Example for 6 hours filter time:
Switch on the pump, if the indication light isn´t red. (Illustration 7)
Press the timer, until the LED "6" turns red. (Illustration 8)
Press the ON/OFF button to start the pump, then the 6H interval will
start.
From this point the filter pump runs for 6 hours non-stop. For
example: If you press the ON/OFF button in this example by 12
o'clock, then the filtration sys-tem is running until 18 o'clock. The
next day at 12 o'clock, it will start again
Initial start with external filter control
If the operation is not required with the included switch, proceed as
follows. Make sure that the battery is fully functional in the timer.
Then adjust clock for 24 hours continuous operation. Now, an
external timer-clock can be preceded and set arbitrarily (or several
inputs and turn-off times are now
Filterpumpen / Timer | 2015_V2
(lithium button cell 3V CR
screws.(Illustration 2)
2032). (Illustra-
(Illustration 6)
.
(Illustration 9)
possible).
Safety
Specified Conditions of Use
• This pump must not be used to supply drink-
ing water or for pumping foodstuff.
• Explosive, flammable, aggressive fluids or
substances detrimental to health as well as
salt water must not be pumped
• This pump is not suitable for commercial or
industrial use.
• Modification of the pump or use of parts not
approved by the manufacturer is not permit-
ted.
• Any other used is not as specified. The
manufacturer assumes no liability for damage
caused by un-specified use.
General Safety Instructions
Children, juveniles and persons not familiar
with the instructions are not permitted to op-
erate the pump. When used as domestic wa-
ter supply all applicable local regulations per-
taining to water supply and waste water dis-
pos-al, plus DIN 1988 (where applicable)
have to be observed. The following residual
risks do principally exist when operating
pumps and pressure vessels and con not be
fully eliminated – even by employing safety
devices.
Hazard gererated by ambient condition!
• Do not expose to rain. Do not operate in
damp or wet environment.
• Do not use the pump in hazardous locations
or near inflammable liquids and gases!
Danger! Risk of electric shock!
• Do not direct water jet directly against the
pump or other electrical parts! Risk of fatal
electric shock!
• Do not touch the plug with wet hands! To
unplug always pull on the plug, not the power
cable.
• The earthed outlet or the plug connection to
an extension cable must be located in an ar-
ea safe against flood-ing.
• Use only extension cables of sufficient lead
cross section. Completely unroll cable reels.
• Do not buckle, squeeze, drag or drive over
power cable and extension cables; protect
from sharp edges.
Page 5 of 44