Fault Finding - IKRA IERM 1434 Manual De Usuario

Cortacésped
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 48

Fault Finding

The following table gives checks and actions that you
can perform if you machine does not operate correctly.
If these do not identify/remedy the problem, contact your
Service Agent.
Warning: Switch off and remove plug from mains before investigating fault.
Symptom
Machine fails to operate
Machine functions
intermittently
Machine leaves lagged finish of
motor labours
Cutting blade not rotating
Excessive vibration/noise
GB | Operating Instructions
Possible
Power turned off
Mains socket faulty
Extension cable damaged
Fuse faulty/blown
Mower in long grass
Motor protector has activated
Extension cable damaged
Machines internal wiring damaged
Motor protector has activated
Height of cut too low
Cutting blade blunt
Underside of machine badly clogged
Blade fitted upside down
Cutting blade obstructed
Blade nut/bolt loose.
Blade nut/bolt loose.
Cutting blade damaged
8
Remedy
Turn power on
Use another socket
Inspect cable, replace if damaged.
Replace fuse
Increase height of cut and tilt mower
Allow to cool for a few minutes and
increase height of cut
At this time do not operate the switch
lever 1 as this will prolong the reset
time of the safety cut out
Inspect cable, replace if damaged.
Contact your service agent.
Allow to cool for a few minutes and
increase height of cut.
At this time do not operate the switch
lever 1 as this will prolong the reset
time of the safety cut out.
Increase height of cut (see height of
Cut Adjustment)
Replace blade (see Blade Mainte-
nance)
Clean machine (see After Mowing/
Storage)
Refit blade correctly (see Blade
Maintenance)
Clear obstruction
Tighten blade nut/bolt
Tighten blade nut/bolt
Replace blade