Output 1-4
Alarm contact
Contact ratings
Contact response
Alarm delay
Wash contact
Contact ratings
Contact response
Rinsing interval
Cleaning time
Limit values (2)
Contact ratings
Contact response
Delay
Switching points
Hysteresis
Digital Communications
RS232 standard
Baud rate
Parity
Display
Keypad
Language
Diagnostic functions
Appendix C
Four standard powered 0/4-20 mA outputs, 500 ohm load maximum, isolated from the
measurement circuitry ; accuracy ±0.05 mA, typical. Outputs are assignable to any
Parameter Set with free scaling in linear, bi-linear, logarithmic or auto range format.
Relay contact, mechanical SPDT, floating
AC< 250 V/< 5 A
DC< 30 V/< 5A
N/C (fail-safe type)
000...600 s
Relay contact, mechanical SPDT, floating
AC< 250 V/< 5 A
DC< 30 V/< 5A
N/O or N/C
0.0 ... 999.9 h
(0.0 h = cleaning function switched off)
000...600 s
2 relay contacts, mechanical SPDT, floating
AC< 250 V/< 5 A
DC< 30 V/< 5A
N/O or N/C
000...600 s
hi-hi / hi-lo / lo-lo
0.0...50.0%
For main program software updates and print outs of configurations
max. distance 15 m (45 ft)
1200, 2400, 4800, 9600, 19.2k and 38.4k
odd, even or none
LC display, 20 character x 4 line, backlit
20 tactile feedback keys
software selectable: English, German, or French for menu and help texts
Sensor
mA outputs
Display
Keypad
Meter
Serial Port
Relays
Selftest