The Filter Unit (Page 4, Fig. C to H)
The filter unit is composed of:
• Cassette filter with fleece
• Sponge
• Central filter
• Pre-filter
• Fastening disk
CAUTION:
• Never wash the components in a washing machine or
a dishwasher!
• Do not use a hairdryer for drying.
• Operate the appliance again only when all components
are completely dry and have been installed correctly.
Proceed as follows to clean the filter unit:
1. Empty the dust container as described above. (Steps
1 - 4).
2. Disassembly of the filter unit
2.1 Turn the filter unit in the
2.2. Pull the filter unit from the dust container. (Fig. D)
2.3. Turn the fastening disk and pull it off. (Fig. E)
2.4. Pull the pre-filter from the central filter. (Fig. F)
2.5. Open the cover of the filter unit. (Fig. G)
2.6. Remove the cassette filter with the fleece and the
inserted sponge. (Fig. H)
3. Clean all parts of the filter unit and the dust container
under running water. You may use a soft brush.
4. Allow all parts to dry completely in air.
5. Assembly of the filter unit
5.1. Place the sponge with the smooth side in the cas-
sette filter onto the fleece.
WARNING:
• Before cleaning remove the mains lead from the socket.
• Under no circumstances should you immerse the appliance in
water for cleaning purposes. Otherwise this might result in an
electric shock or fire.
CAUTION:
• Do not use a wire brush or any abrasive items.
PC-BS3040_IM
Outlet Filter (HEPA-Filter)
The appliance is also equipped with an outlet filter.
It is located on the back of the unit next to the parking aid.
1. Push down the lever (13) and remove the ventilation
2. Remove the filter insert and clean it. You can brush out
3. Reinsert the filter. The guide pins must point downwards.
direction. (Fig. C)
4. Put the ventilation grille back on the appliance. Observe
Turbo Brush
• To remove hair from the brush roller, fold up the brush
• Cut threads and hair that have rolled up on the brushes
• To remove stubborn impurities, loosen the nut and dis-
Cleaning
• Do not use any acidic or abrasive detergents.
5.2. Place the cassette filter on the central filter.
5.3. Close the cover. It must lock mechanically.
NOTE:
The cover can only be closed with the cassette
filter inserted.
5.4. Set the pre-filter to the central filter.
NOTE:
• The pre-filter has recesses of different sizes,
which match the tabs on the central filter.
• Make sure the rubber seals are inserted
correctly.
5.5. Set the fastening disk onto the pre-filter and tighten
it by turning.
5.6. Replace the filter unit in the dust container: Set
the guide tab on the filter unit to the
Tighten the filter unit by turning it in the
grille.
the filter.
the guide lugs. The ventilation grid must engage audibly.
attachment. To do this, loosen the locking mechanism
( ) on the right side.
with a small pair of scissors.
assemble the brush. For assembling, please refer to the
illustrations on page 5!
CAUTION:
symbol.
direction.