NOTE: Please set the scale unit before modifying the setting. Converting a value into another unit might cause
a resolution loss.
c. Alarm Modes
• In normal display mode, press ALARM to enter the HI alarm mode.
• Press ALARM again to enter the LO alarm mode. After the first press the display will be refreshed to show
the current HI and LO alarm values. The Normal Alarm value will be displayed only for values already
activated. All other values will be displayed as - - - or - -.
• Press ALARM to return to normal display mode.
• In the HI alarm mode, press SET to select the following modes: Time alarm (h / m) – Indoor humidity HI
alarm – Indoor temperature HI alarm – Outdoor humidity HI alarm – Outdoor temperature HI alarm – Wind
chill HI alarm – Dew Pont HI alarm – Pressure HI alarm – Wind speed HI alarm – Gust speed HI alarm – 1h
rain HI alarm – 24h rain HI alarm.
• In the LO alarm mode, press SET to select the following modes: Time alarm (h / m) – Indoor humidity LO
alarm – Indoor temperature LO alarm – Outdoor humidity LO alarm – Outdoor temperature LO alarm –
Wind chill LO alarm – Dew point LO alarm – Pressure LO alarm.
• In both alarm modes, press + or MIN / MAX to modify the alarm value. Hold + pressed for 3 seconds to
modify the value rapidly. Press ALARM to switch the alarm on or off (if the alarm is enabled, the speaker
icon will appear on the display). Press SET to confirm the settings. Press SET to scroll through the setting
options and to return to the normal display mode.
• Press HISTORY to return to the normal display mode.
Cancelling the temperature alarm while sounding
• When a set weather alarm condition has been activated, that particular alarm will sound and flash for 120
seconds. Press any key to mute the alarm. If the alarm is activated again within 10 minutes, the alarm will
not sound but will continue to flash until the weather conditions have become stable. This feature is useful
to avoid repeated triggering for the same value.
• The alarm will automatically reactivate once the value has fallen below the set temperature value or if a
new value is entered.
The outdoor weather alarm
When a set outdoor alarm has been triggered, it will flash on the
LCD display. The general outdoor alarm icon and HI / LO alarm
icon will flash accordingly. Example: In outdoor temperature mode,
the dew point icon will flash along the outdoor alarm and the HI
alarm icons when the dew point HI alarm is triggered. This will
indicate that the current alarm source is from the dew point.
d. History Mode
• In normal display mode, press HISTORY to enter the history
mode.
• Press + to select the record over the past 24 hours at
increments of -3h, -6h, -9h, -12h, -15h, -18h, -21h and -24h.
• Press HISTORY again to return to the normal display mode.
e. MIN / MAX Mode
• Press MIN / MAX to enter the MAX mode. MAX and the maximum record will be displayed.
• Press MIN / MAX to enter the MIN mode. MIN and the minimum record will be displayed.
• Press MIN / MAX to return to the normal display mode.
WS1070_v3
Temperature display mode
Dew point HI alarm triggered