ENGLISH
•
Hose connection between compres-
sor and air tool leaky.
− Check air hoses, replace defec-
tive parts if necessary.
9. Technical Specifications
Suction capacity
Free air delivery (volume flow rate)
Filling rate
Working pressure (compression end pressure)
Pressure vessel volume
No. of air outlets
Pump model
No. of cylinders
Motor speed
Motor capacity
Supply voltage (50 Hz)
Rated current
Fuse protection min.
Degree of protection
Max. overall cable length when using extension cables:
2
– at 3 x 1.0 mm
lead cross section
2
– at 3 x 1.5 mm
lead cross section
2
– at 3 x 2.5 mm
lead cross section
Dimensions length x width x height
Weight
Sound pressure level at 1 m max.
10
7. Repairs
Danger!
Repairs to power tools must be
carried out by qualified electricians
only!
Power tools in need of repair can be sent
to one of the adresses listed on the sec-
ond-last page.
Please attach a description of the fault to
the power tool.
8. Environmental Protection
The machine's packaging can be 100 %
recycled.
Worn out machines and accessories
contain considerable amounts of valua-
ble raw and plastic materials, which can
be recycled.
These instructions are printed on chlo-
rine-free bleached paper.
l/min
l/min
l/min
bar
l
-1
min
W
V
A
A
10 (time-lag)
m
m
m
mm
905 x 410 x 690
kg
dB (A)
235
125
145
8
50
2
F 245
1
2850
1.5
230
6.8
IP 20
10
25
25
25
88 ± 3