Nikon Laser 550A S Manual De Instrucciones página 28

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Operation and internal display
Jp
【7】 Vertical separation (height between two points) mode
En
Fr
Operation/Results
Work
Es
7  Measurement with Vertical separation (height between two points) mode (only at FULL mode setting)
Pt
7-1
Seeking your target
Vertical separation
(Align the reticle with target)
(height betweentwo points) (1st target)
7-2
Measurement
(Laser irradiate symbol
is displayed)
7-3
Failure to measure
Follow by 7-1
Repeat 7-1, 7-2, 7-3 until measurement
is complete.
7-4
Measurement OK
Height of 1st target (from Horizontal)
followed by 7-5 or 7-6.
7-5
Data display after
(1)
Linear distance (1st target)【3】
switching modes
(2)
Horizontal distance (1st target)【4】
(3) Height (from horizontal) (1st target)【5】
If the mode is switched,
the 2nd target cannot be
(4)
Angle (from horizontal) (1st target)【6】
measured
(5)
Vertical separation
Switching the measurement
(height between two points)
unit changes it for each
7-5-(follow by 6-1 or 6-2)
mode. The POWER button
can be used to measure in
(6-1)
Return to 7-5-(1), then repeat.
each mode
(6-2)
See the relevant section.
follow by 7-3 or 7-4
7-6
Aiming (2nd target)
Vertical separation
(Align the reticle with target)
(height between two points) (2nd target)
(Result shown is the height of the 1st target)
7-7
Measurement
(Laser irradiate symbol is
displayed)
54
Display examples
Button
Display
meter
yards
Elevation (°) Depression(°)
blinks
POWER
blinks
104
114
blinks
MODE
MODE
224
245
MODE
104
114
MODE
25
MODE
0.0
0.0
blinks
MODE
After aiming,
POWER
104
114
blinks
POWER
Operation/Results
Work
7-8
Failure to measure
Follow by 7-6
Repeat 7-6,7-7 and 7-8 until measurement
is complete
7-9
Measurement OK
Vertical separation
(height between two points)
After 2 seconds move to7-10
7-10
Vertical separation
(height between two points)
Follow by 7-11 or 7-1
7-11
Date display after
(1)
Linear distance (2nd target)【3】
switching modes
(2)
Horizontal distance (2nd target)【4】
(3) Height (from horizontal) (2nd target)【5】
Switching the
measurement unit
(4) Angle (from horizontal) (2nd target)【6】
changes it for each
(5)
Vertical separation
mode. The POWER
(height between two points)
button can be used to
Follow by 7-11-(6-1) or 7-11-(6-2)
measure in each mode
(6-1)
Return to 7-11-(1), then repeat
See the relevant section.
(6-2)
Follow by 7-3 or 7-4
Regardless of process, after 30 seconds
8
Power off
since your last operation, power turns off.
Display examples
Button
Display
meter
yards
Elevation (°) Depression (°)
blinks
64.0
64.0
blinks
MODE
228
249
MODE
224
245
MODE
40.0
43.8
MODE
10
MODE
64.0
blinks
MODE
After aiming
POWER
30 seconds
without operation
Jp
En
Fr
Es
Pt
55

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido