INSTALLATION CHECKLIST

1. Tank location:
– Is room size less than 10' x 10' x 7' (700 cu. ft.)? If yes, louvered door or similar ventilation is needed.
– Back of unit away from wall by 7 inches.
– Front of unit is free and clear.
– Is the water heater level? If no, add shims under the base of the unit.
2. Plumbing connections:
– Does not prevent air filter removal.
– No leaks after filling the tank with water, either when water is flowing or not.
3. Condensate lines are in place:
1) Short tube on upper drain nozzle.
2) Longer tube on lower drain nozzle and directed into a floor drain or a condensate pump.
4. Temperature and pressure-relief valve is working and drain line completed per local code.
5. Electrical connection does not prevent air filter removal.
6. Verify control panel displays 120°F Hybrid mode.
7. Front cover is in place.