Parallelogram: Decreases or increases the tilt of the sides
either to the left or right.
Bow (Pincushion Balance): Decreases or increases the
curvature of the sides either to the left or right.
Rotates: Rotates the image.
Degauss: Select the degauss icon on "Icon select window"
and push "SELECT" button. It will eliminate the stray
magnetic field and correct the scan of the electron beam,
which affect the purity, focus and convergence.
Note:
Color Temperature:
9300K (75F)
Select the Color Temperature icon on "Icon Select
Window" and push "SELECT" button.
It can be switched to change the color Temperature.
9300 (95F)
(9300K, 7550K, 6550K, user)
OSM: There are 3 background colours (Blue, Black, and
white). These can be selected by "SELECT" button after the
selection of "OSM" on "Icon select window".
EXIT: To exit OSM window. Select EXIT on "Icon select
exit (75F)
window", then push "SELECT" button.
MultiSync 95F
EXIT: To exit OSM window. Select ESC on "Icon select
window", then push "SELECT" button.
Horizontal Moiré Canceler: Reduces horizontal moiré
levels.
Vertical Moiré Canceler: Reduces vertical moiré levels.
Note:
01b_english
Allow a minimum interval of 20 minutes to elapse
between uses of the degauss function.
If you do not push buttons within 10 seconds in
OSM condition, the window will automatically
disappear.
English-6
6
09.10.2000, 13:39 Uhr