synchronized instant reception
12 or 24 hour display
perpetual calendar
time zone setting
alarm clock
LED backlight
wall mount or standing free
5.
Overview
Refer to the illustrations on page 2 and 3 of this manual.
A
upper pole
B
lower pole
C
top support
D
anemometer
E
wind vane + direction sensor
a
MENU button
b
ENTER button
c
UP button ()
1
Weather forecast
2
Barometric pressure
3
Barometric trend
4
Date
5
Memory
6
Time
7
Indoor humidity
8
Indoor temperature
9
transmitter low battery indicator
6.

Setting up the stations

1. Connect the lower pole [B] with the upper pole [A].
2. Place the anemometer [D] on the top support [C] and fix with a bolt and nut.
3. Place the wind vane [E] on the top support [C] and fix with a bolt and nut.
4. Place the top support [C] on top of the upper pole [A] and fix with a bolt and nut.
5. Mount a side support [F] on the pole [A+B] and place the rain sensor [G] on top. Secure it with a screw.
6. Mount the second side support [F] on the pole [A+B].
7. Place the solar panel [H] on top of the shelter [I] and secure it with a bolt and nut.
8. Make all necessary connections:
Connect the anemometer [D] to the wind vane [E] phone jacket.
o
Connect the wind vane [E] to the thermo-hygrometer [J] WIND phone jacket (left).
o
Connect the rain sensor to the thermo-hygrometer [J] RAIN phone jacket (right).
o
9. Insert 2 x AA rechargeable batteries (incl.) into the thermo-hygrometer [J] respecting the polarity as
indicated inside the casing. Only use rechargeable batteries!
10. To ensure DCF reception, immediately insert 3 x AA batteries into the receiver respecting the polarity. Refer
to the section Initialization below for more information on DCF. Note that the receiver is located inside the
thermo-hygrometer
11. Slide the thermo-hygrometer [J] into the shelter [I].
12. Place the thermo-hygrometer [J] on top of the second side support [F] and secure it with a screw.
13. It is strongly recommended to test the station before mounting it outdoors.
14. Wait for the two stations to synchronize. This synchronisation may take a couple of minutes. Do not touch
any button during synchronisation. Once the synchronisation finishes, make sure that all components work
properly.
V. 05 – 08/11/2016
WS3080
F
side support
G
rain sensor
H
solar panel
I
sensor shelter
J
thermo-hygrometer (under shelter)
DOWN button ()
d
e
ALARM ON/OFF button(
f
HISTORY button
10 Outdoor reception signal
11 Outdoor humidity
12 Outdoor temperature
13 Wind direction
14 Wind speed/gust
15 UV index
16 Rainfall
17 Light intensity
18 Radio Controlled Clock (RCC) indicator
5
)