INSTALLAiTION
INSTRUCTIONS
17
Venting
the
Dryer
_WARNING
To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow
basic precautions,
including
the following:
• Do not crush or collapse ductwork.
Failure to follow
these instructions
can result in fire or death.
• Do not allow ductwork
to rest on or contact
sharp
objects.
Failure to follow
these instructions
can result
in fire or death.
• if connecting
to existing ductwork,
make sure it
is suitable and clean before
installing the dryer.
Failure to follow these instructions
can result in fire or
death.
• Venting must conform to local building
codes.
Failure to follow these instructions
can result in fire or
death.
• Gas dryers MUST exhaust to the outdoors.
Failure to follow these instructions
can result in fire or
death.
• Use only 4-inch (10,2 cm) rigid or flexible
metal
ductwork
inside the dryer cabinet
and for venting
outside.
Failure to follow these instructions
can result
in fire or death.
• To reduce the risk of fire, combustion,
or
accumulation
of combustible
gases, DO NOT
exhaust dryer air into an enclosed and unventilated
area, such as an attic,
wall, ceiling,
crawl space,
chimney, gas vent, or concealed
space of a
building.
Failure to follow these instructions
can result
in fire or death.
• To reduce the risk of fire, DO NOT exhaust the dryer
with plastic or thin foil ducting.
Failure to follow these instructions
can result in fire or
death.
• The exhaust duct must be 4 inches (10.2 cm) in
diameter
with no obstructions.
The exhaust duct
should be kept as short as possible. Make sure
to clean any old ducts before
installing your new
dryer. Failure to follow these instructions
can result in
fire or death.
. Rigid or semirigid
metal
ducting is recommended
for use between
the dryer and the wall. In special
installations
when it is impossible
to make a
connection
with the above recommendations,
a
UL-Jisted flexible
metal
transition
duct may be used
between the dryer and wall connection
only. The
use of this ducting will affect
drying time. Failure to
follow these instructions
can result in fire or death.
. DO NOT use sheet metal screws or other fasteners
which extend into the duct that could catch lint and
reduce the efficiency of the exhaust system. Secure
all joints with
duct tape. Failure to follow these
instructions
can result in fire or death.
. To maximize
operating
results, please observe
the duct length limitations
noted in the chart next
page. Failure to follow
these instructions
can result in
fire or death.
. Ductwork
is not provided
with the dryer. You
should obtain the necessary
ductwork
locally. The
end cap should have hinged dampers to prevent
backdraff when the dryer is not in use. Failure to
follow these instructions
can result in fire or death.
. The total
length of flexible
metal
duct shall not
exceed 8 ft. (2.4 m)
. In Canada, that only those foil-type
flexible
ducts,
if any, specifically
identified
for use with the
appliance
by the manufacturer
shall be used. in the
United States, that only those foil-type
flexible ducts,
if any. specifically
identified
for use with the appliance
by the manufacturer
and that comply with the Outline
for Clothes Dryer Transition
Duct, Subject 21S8A, shall
be used.