Condition
Engine does not stop
Engine stops when throttle is closed
Blade continues rotating when throttle
is closed
16
Cause
Stop switch failure
Idle speed is too low
Idle speed is too high
Throttle wire is too taut
Remedy
Set the choke lever to START position to stop the
engine
Cease use immediately and contact Hitachi
Authorized Service Centers
Contact Hitachi Authorized Service Centers
Contact Hitachi Authorized Service Centers