Descargar Imprimir esta página

DeVilbiss StartingLine 802343 Manual De Instrucciones página 2

Publicidad

Idiomas disponibles

Idiomas disponibles

Page 2
SB-2-610-H
READ BEFORE ATTACHING THE AIR HOSE
FULL SIZE GUN: 30 PSI inlet pressure provides 10 PSI at the air cap. Consumes 13 CFM.
TOUCHUP GUN: 30 PSI inlet pressure provides 10 PSI at the air cap. Consumes 8 CFM.
SET-UP AND ADjUSTMENT INSTRUCTIONS
1. Attach cup to gun and
flush solvent through gun
to remove oils.
2. Tighten packing nut—see
instructions.
3. Fully open fan and fluid
needle controls (turn
counter-clockwise).
A failure resulting in injury or damage may be caused by pressure
beyond top of scale, excessive vibration or pressure pulsation, exces-
sive instrument temperature, corrosion of the pressure containing
parts or other misuse of the air adjusting valve with gauge.
Spray a test area. Turn the fluid needle
adjusting knob counterclockwise until a
full coat is obtained.
If the finish is too sandy and dry, the
material flow may be too low for the
atomization air pressure being used.
Turn the fluid needle adjusting knob
counterclockwise to increase fluid flow.
If the finish sags, there is too much mate-
rial flowing for the atomization air pressure
being used. Turn the fluid needle adjusting
knob clockwise to decrease fluid flow.
Pattern width can be altered by turn-
ing spreader adjustment valve, either
clockwise to decrease the width or coun-
terclockwise to increase the width.
Adjust inlet air pressure to provide a uni-
form dispersion of atomized paint through-
out the pattern. Keep air pressure as low
as possible to minimize bounce-back and
overspray. Excessive pressure will result in
split spray patterns. Inadequate pressures
will cause heavy centered patterns and
poor atomization.
Fluid Tip
Size (mm) Applications
1.0
General purpose, light to medium
viscosity material.
1.3
Top coats.
1.5
Top coats and primer sealers.
1.8
Primers.
ATTENTION!
HVLP AIR SUPPLY REQUIREMENTS
NOTE: USE 5/16" OR LARGER I.D. AIR HOSES
4. If desired, attach air adjust-
ing valve with gauge and/
or quick disconnect to air
inlet, then attach hose.
5. Spray test and adjust air
pressure, fan size, and
fluid flow as required.
R e c o m m e n d e d
s p r a y
distance is 6-8 inches.
CLEANING
For routine cleaning, it is not necessary
to remove cup from gun. Remove lid and
properly dispose of any excess paint. Pour
in a small amount of clean solvent. The
amount will vary with different coatings and
solvents. Reinstall lid. Shake cup to wash
down the inside surfaces. Pull trigger to
allow some solvent to be flushed through
gun. Remove lid and pour out dirty solvent.
Add a small amount of clean solvent and
repeat procedure. Wipe exterior of lid with
a clean cloth and clean solvent.
If a paint filter was used in the bottom of
the cup outlet, it should be removed and
cleaned at this time.
To clean air cap and fluid tip, brush exte-
rior with a stiff bristle brush. If necessary
to clean cap holes, use a broom straw
or toothpick if possible. If a wire or hard
instrument is used, extreme care must
be used to prevent scratching or burring
of the holes which will cause a distorted
spray pattern.
To clean fluid passages, remove excess
material at source, then flush with a suit-
able solvent. Wipe gun exterior with a
solvent dampened cloth. Never completely
immerse in solvent as this is detrimental
to the lubricants and packings.
PREVENTIVE MAINTENANCE
PACkING ADjUSTMENT INSTRUCTIONS
AIR CAP
PACKING
NUT
FLUID NEEDLE
The packing nut is intentionally left loose so the PTFE packing
does not take a "set" before the spray gun is used. This allows
full utilization of the packing.
Spray Gun Lubrication
Apply a drop of SSL-10 spray gun lube at
trigger bearing stud and the stem of the air
valve. The shank of the fluid needle where
it enters the packing nut should also be
oiled. The fluid needle packing should be
kept soft and pliable by periodic lubrication.
Make sure the baffle and retaining ring
threads are clean and free of foreign matter.
Before assembling retaining ring to baffle,
clean the threads thoroughly, then add two
drops of SSL-10 spray gun lube to threads.
The fluid needle spring and air valve spring
should be coated with a very light grease,
making sure that any excess grease will
not clog the air passages. For best results,
lubricate the points indicated, daily.
A. Trigger Points
B. Packing
C. Adjusting Valve
D. Baffle/Air Cap Threads
FAN CONTROL
FLUID NEEDLE CONTROL
Before using this spray gun,
the packing nut should be
adjusted as follows:
1. Tighten packing nut until
fluid needle starts to bind
in the packing.
2. Loosen packing nut just
enough so the fluid needle
moves freely.
A
C
D
B

Publicidad

loading

Este manual también es adecuado para:

Startingline 802789