4.4
STORAGE
•
Store the machine in a dry place, if possible keeping it in its packaging.
•
Do not remove the protection from the openings.
5
INSTALLATION
5.1
INSTALLATION CONDITIONS
•
Make sure the conditions of use as described in section 3 are complied with, then proceed with installation of the machine as
specified below.
Danger due to limited visibility in the place where the unit is installed!
Make sure to always keep an eye on the installed unit when carrying out any operation in the installation area.
The control elements must be placed so that the installed unit can be seen.
Danger due to vibration!
Regularly check the fixing of the unit to the support structure.
Excessive vibration of the unit can seriously damage the machine.
Vibration dampers are supplied with machines from K07 to K12.
NOTE FOR THE USER
On request, vibration dampers are also available on the other machines.
•
The unit's support surface must be flat, sturdy,
stable and as level as possible.
•
The unit must be installed on a structure that does not transmit
vibrations. Do not install the unit on structures that can transmit or
amplify the noise.
•
Installation of the unit must always be done using vibration dampers.
•
Installation of the unit must ensure that motor ventilation is not
impeded by obstacles placed in the immediate vicinity. Therefore, the
motor air intake must remain free, ensuring a distance of at least
50mm between the motor fan cover and any structure.
•
Connect the pipes using flexible sleeves, without resting the weight of
the pipes on the unit, with the exception of a possible filter in case of
suction in the place.
•
Determine the dimensions a, b, c to allow adequate space for
installation of the unit with its accessories (Dimensions available in the
first section).
When installed outdoors, protect the unit against
ATTENTION!
the sun and weather.
FPZ-MI-K-MS-MOR-USA-15-R03
20 / 84
2 in