Descargar Imprimir esta página

Hydraulic Connection - Panasonic PAW-DHW270C1F Manual Del Usuario

Calentador de agua termodinámico

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 123
WARNINGS
3/ If the appliance is to be installed in a room or location where
the ambient temperature is permanently above 35°C,
provide ventilation in the room.
5/ Do not use volumes V0, V1 or V2
if installing this product in a bathroom.
Volume V2 can, however, be used
if the dimensions cannot accommodate
another size.
6/ Place the appliance in an accessible location.
7/ Refer to the installation illustrations
in the "Installation" section.
This product is designed to be used at a maximum altitude of
2000m.

HYDRAULIC CONNECTION

You must install a frost-free safety device (or any other pressure
relief device), which is new, with 3/4" (20/27) dimensions and 0.7
MPa (7 bar) pressure on the inlet of the water heater, which
complies with local standards.
The dimensions of the space required for the correct installation
of the appliance are specified in the figure on page 9.
A pressure reducer (not supplied) is required when the supply
pressure is greater than 0.5 MPa (5 bar) - which must be attached
to the main supply.
Connect the safety device to a drain hose, kept uncovered, in a
frost-free environment, with a continuous downward slope for
the release of excess water from the heater or if you are
emptying the water heater.
The operating pressure of the heat exchanger circuit must not
exceed 0.3 MPa (3 bar) and its temperature must not exceed
100°C.
42

Hide quick links:

Publicidad

loading

Este manual también es adecuado para:

Paw-dhw200fPaw-dhw270f