SPRAY NOZZLE MAINTENANCE
Remove the Spray Nozzles (A) once a week. See Figure 7. Soak the nozzles overnight in vinegar to remove chemical deposits. NOTE: Remove
by gripping and turning a quarter turn counter-clockwise.
SOLUTION SCREEN MAINTENANCE
Once a week (or more often if necessary), clean the Solution Screen (6). Drain the solution tank. Open the Solution Tank Lid (5), reach inside the
solution tank and pull up on the solution fi lter to remove.
POWER CORD MAINTENANCE
Once a week (or more often if necessary), check the power cord for cracked or damaged insulation, exposed wires in the cord or plug, and damaged
or missing ground pin. Repair or replace damaged cord or plug immediately.
ADJUSTING THE BRUSH PRESSURE
Simply turn the Brush Pressure Adjustment Knob (20) clockwise to increase brush pressure and counter-clockwise to decrease the brush pressure.
POWER BRUSH MAINTENANCE
Check the brush daily. Remove any built-up string, hair or carpet fi bers. When the machine is not in use it should be placed in the storage position.
This will prevent the brush from taking a set which will increase the brush life and maintain the performance of the brush.
REMOVING THE BRUSH
CAUTION!
Turn the power switch off (O) and unplug the machine, before changing the brush.
1
Empty both the recovery and solution tanks and tip the machine over onto its right
side.
2
See Figure 7. Rotate the brush until the Drive Lug (B) is in a position where the
fi ns on the drive lug are perpendicular to the bottom of the machine.
3
Grab the brush at the end with the Brush Retainer Clip (C) and pull straight out.
4
Install a new brush at the drive lug end fi rst then push in the other brush end in until
it snaps into the retainer clip.
EN
FORM NO. 56041660 - Clean Track
ENGLISH / A-11
FIGURE 7
16, 18 - A-11
®