Manual Binding
1. Repeat steps 6 to 8 of the Binding with Homesys section.
2. Press and hold the learning key "F" (as shown in Figure 4) for more than 3
seconds until the green strobe LED turns off, then quickly release the
learning key. The Green LED will flash repeatedly. This implies HSE03
has now entered the binding mode and is waiting to receive binding
signals from the gateway.
3. Within 5 seconds the green LED will stop flashing indicating the learning
procedure is completed. The screen below will appear indicating the
process is successful.
Testing
HSE03 can be tested with Homesys smartphone App by changing the security
mode between ARM and DISARM on the App and the listening for voice
indication from HSE03.
If there is no response from HSE03 please check the "Troubleshooting".
Mounting the HSE03
The HSE03 should be mounted inside the building in a position that is clearly
visible and at a height which is relatively inaccessible to an intruder. It is also
suggested not to mount the unit in the basement to avoid poor transmission.
1. Use the backplate as a template to mark and drill the position of 3 mounting
holes on the wall. Fix the backplate to the wall using the plastic wall plugs and
fixing screws provided.
2. Slide the unit down to the backplate and fasten the locking screw clockwise.