H: The TIMER indicator
light indicates that the
timer function has been
switched on.
In case of any malfunc-
tioning the information
display will tell you what
is the matter.
The available temperature settings range from 6°C minimum to 28°C maximum.
When the heater has been unplugged for more than 10 minutes (or after a power fail-
ure), the temperature will reset to the factory setting of 20°C.
F
USING THE TIMER
The timer allows you to switch on the heater automatically at a preset time.
In order to switch on the timer, the correct time must have been set (refer to Section C)
and the heater should be off. Follow the procedure below:
1
Press the
button M and then the TIMER key P immediately after that.
The TIMER light and the information display L will start blinking.
2
Use the adjustment keys O to set the time at which the heater must ignite.
Use the key (Nhour) to set the hours and the key (Mmin.) to set the minutes (inter-
val of 5 minutes).
3
After approximately 10 seconds the information display will show CLOCK
again and the TIMER indicator light will light up, indicating that the timer
function has been activated (Fig. H).
4 The timer will ensure that the room will have been heated to approximately
the required temperature at the set time.
When you want to switch off the heater and ignite it again with the timer, all you
have to do is press the TIMER key (refer to Section G).
Press the
button M once to clear the timer setting.
G
SWITCHING OFF THE HEATER
There are two ways to switch off the heater.
1
Press the
button M. The information display will show the CLOCK
signal. Within approximately one minute the flame will have extinguished.
2
Press the TIMER key P, when you want to switch off the heater and ignite it
again with the timer the next time. This not only switches off the heater, but
it also activates the timer function. You can change the required time with the
adjustment keys O (refer to Section F).
H
THE INFORMATION DISPLAY
The information display L not only serves as an indicator of the (set) time and tempera-
ture (Sections C, E, and F), it also indicates any malfunctioning of the heater. The code
on the information display tells you what is the matter:
CODE
INFORMATION
e - 0
Temperature within the heater too high.
f - 0
Power interrupted.
e - 1
Faulty thermostat.
f - 1
Faulty burner thermistor.
e - 2
Starting problems.
e - 5
Tipping-over protection.
e - 6
Poor burning.
e - 7
Room temperature
above 32°C.
WHAT TO DO
Cool-down and re-ignite.
Re-ignite the heater.
Contact your dealer.
Contact your dealer.
Contact your dealer.
Re-ignite the heater.
Contact your dealer.
If necessary,
re-ignite the heater.
4