6. Installation
For safety reasons it is important to read all of the
enclosed information before installation of this equip-
ment. In addition, the legislation in force at the time of
purchase must always be considered in connection
with the installation and mounting of this equipment,
no matter the contents of this manual.If there are mat-
ters of dispute please contact your dealer.
6.1. Noise
Sound level according to ISO 11202; Below 71 dB
6.2. Directions for Placing/Storage
• The unit should be placed in frost-
free rooms only.
6.3. Transportation
For secure transportation of the unit, we recommend
always to ensure, that the unit can not slide or tip.
The unit might have to be secured with straps.
Transportation of the unit only in upright position.
In case the unit is moved at a temperature of approx
or below 0°C (32°F), you must always make sure that
the the unit has been fully emptied for water. If this is
not the case, you may damage the unit.
6.4. Vibrations
Hand-arm vibrations according to ISO 5349-1
6.5. Electrical connection
• Before the unit is connected to the
electrical outlet make sure the outlet
is connected to a fuse of 16A/25A.
• Make sure the outlet fits the plug on
the unit, if not change the plug on
the unit. Do not change the plug your
self get a certified electricians to do
the plug change.
6.6.
Hybrid Typhoon 40 ONLY!
Earth Leakage Circuit Breaker (ELCB).
When using an earth leakage circuit breaker (ELCB) also
known as a residual current device (RCD) or a residual
current circuit breaker (RCCB) in a system that incorpo-
rates a variable speed drive connected to 3 phase 400 V.
The trip level of the ELCB has to be 300 mA.
(30 mA used in house hold will malfunction due to earth
leakage)
6.7. Water Connection
• Before the unit is connected to the water
supply pipe, the supply line should be
rinsed carefully in order to remove coarse
impurities and metal shavings.
14
• Minimum internal diameter of the supply
hose must be at least 3/4" external.
• The pressure loss in the supply line must
be held as low as possible by
- avoiding long supply pipes
- mounting low pressure resistance
ball valves and
- avoiding fittings with high pressure
loss
Max. allowed temperature of supply water: 70°C
Max. allowed pressure of supply water:
Water consumption at rinsing mode:
For an optimum functioning of the injector
system, we recommend installing a filter
on the inlet to avoid impurities.
6.8. Air Supply
The unit have an internal air supply via a
compressor.
No special actions are necessary before
use.
6.8.1.
Supply of chemical products
Unit without User Pack System.
• Place the cans with chemical products in the can
holder
• Check the suction filters for impurities.
• Put the suction hoses into the cans below product
level and avoid suction of air.
• After pre-rinsing, check again that the hoses is
sufficiently below product level and avoid suction
of air during foam or spray operation.
• After use of and when changing product as well
as after use of the unit, remove the hoses from the
cans and rinse the product inlet lines and injectors
with clean water.
Unit with User Pack System
See drawing no 110004594.
• Place the specially designed User Pack in the
automatic holder.
• If changing to a different product when ending the
cleaning process, rinse the product inlet line with
clean water as follows:
Replace the User Pack containing product by one
with clean water; place the foam nozzle and open the
spray gun/outlet valve. The product inlet line is now
rinsed with clean water before use of another product.
.
6.9. Hose Connection
• The special hose fitted with spray gun/outlet valve
is connected to the outlet quick coupling of the unit
(layout drawing).
• Maximum hose length: 25 m.
• It is recommended only to use Nilfisk Food hoses,
which have been tested for chemical resistance
and general wear and tear.
4 bar
30 l/min