ondItIoner
SUBMENU ITEM
Clear Faults
Fault 1
Fault 2
Fault 3
Fault 4
Fault 5
Fault 6
SUBMENU ITEM
Time Stamp (TS)
Mode (MD)
Compressor Reduction Mode
(CRM)
Requested and Actual % Demand
(RAD)
Requested and Reported ID CFM
(RAF)
Outdoor Air Temperature and
Outdoor Fan RPM (ATOF)
Discharge Temperature and
Outdoor Coil Temperature (DCT)
Outdoor Liquid Temperature
(DLT)
Pressure Sensor and Suction
Temperature (PSDST)
f
m
dvanced
eature
INDICATION/USER
MODIFIABLE OPTIONS
NO or YES
Most recent AC fault
2nd most recent AC fault
3rd most recent AC fault
4th most recent AC fault
5th most recent AC fault
6th most recent AC fault
COMMENTS
Provides compressor run time in hours.
Current system operation mode (COOLING, COOLING STARTUP, OIL RETURN,
STOP).
Displays ON or OFF status. ON indicates that the reduction mode is operating and
the compressor is running at a lower speed than the cooling load would normally
require.
Displays a 0-100% value, based on a ratio of the requested cooling demand to what
the system is actually providing.
Compares the indoor airflow to what the indoor equipment has reported.
Displays the outdoor air temperature as well as the outdoor fan speed (RPM).
Displays the discharge temperature and outdoor coil temperature sensor readings.
Displays the outdoor liquid temperature sensor reading.
Displays the pressure sensor reading which is taken slightly upstream of the suction
accumulator and outdoor suction temperature sensor reading.
enu
diAGnoSticS
COMMENTS
Selecting "YES" clears the fault history.
StAtUS
30
30