Descargar Imprimir esta página

Miele PW 6107 Instrucciones De Montaje página 42

Ocultar thumbs Ver también para PW 6107:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 35
Produktgruppe 512
42 von 42
Connect and calibrate the dispensing pump:
Knock out the pre-punched hole on the machine rear panel.
Install the cable guide on the rear panel; see Fig. 3.
Connect the dispensing pump in accordance with the wiring diagram.
If dispensing pump capacity is known, this value can be entered directly in the operator level (e.g., dispensing pump 7).
Operator level Main menu Settings Dispensing pump capacity Dispensing pump 7: No .....ml/min OK Back
(until diskette symbol appears) Diskette symbol to save the capacity.
If dispensing pump capacity is not known, the dispensing pump should be calibrated in the operator level (e.g., dispensing pump 7).
Operator level Main menu Settings Dispensing calibration Dispensing pump 7.
Place the dispensing pump's suction hose in a container with a fill line.
Fill the container to the fill line.
Press the 0/1 button (dispensing pump will run for 60 seconds).
Use a beaker or measuring cup to refill the container to the fill line.
Determine the dispensed amount in the beaker/cup and enter it in the display (V:.....ml).
Press the diskette symbol to save the dispensed amount.
Register the refill message (e.g., dispensing pump 7).
Operator level Main menu Settings Dispenser refill message Dispensing pump 7: No
one level) Diskette symbol to save the refill message.
Check dispensing in all programs and adjust as necessary.
Carry out a functional check.
Register water recycling (WRG).
Service Settings Basic settings Water intake Valve block 2 Water valve 3 : K6 OK Back 2x (to go back 2 levels)
Diskette symbol to save WRG registration.
Carry out a functional check.
Back up all data via service mode.
Service Backup Backup data for EW Overwrite existing data? Diskette symbol to overwrite EW data.
To quit service mode, switch off the machine.
Finish up:
Re-install the machine lid.
Carry out a safety check.
Reconnect the machine to the electrical and gas supplies and switch it on.
am
06.02.2014
Diese Unterlagen dürfen ohne unsere Genehmigung weder vervielfältigt noch Dritten zugänglich gemacht werden. Eigentumsrechte vorbehalten.
Umbau- und Montageanweisung
M.-Nr. 09087201
Yes OK Back (to go back

Publicidad

loading

Este manual también es adecuado para:

Pw 6137Pw 6167Pw 620709087201