Switching on and off
Check connecting line and plug on damages first.
Push the button MAGNET ON so that the magnet adheres and the grip of the drill stand is ensured.
For non-magnetisable materials use the Rotabest Vacubest (Prod.-No. 18150).
When working on walls and ceilings secure the machine with the safety belt.
At this work we recommend cooling the tool with a spray. For example Alfra BIO 4000, prod. No. 21040.
Push the button MOTOR ON to start the motor.
To switch off the machine proceed in reverse order, MOTOR OFF and then MAGNET OFF.
Signal LED
The LED above the control panel shows the operating status of the machine and the adhesive force of the magnet.
LED aus
LED grün
LED rot
LED rot
Magnet off.
Motor off.
Magnet on and sufficient adhesive force.
Motor can be switched on/off as desired.
Magnet on and very low adhesion. Work only with very low feed.
Motor can be switched on/off as desired.
Magnet on and insufficient adhesion.
Motor cannot be activated or motor emergency stop.
14