CONNECTING PERIPHERALS
1. Description of the various peripherals
Key Description
1
230 V Integrated blinking Orange Warning Light
2
Reflex Photo-electric Cells
3
Key-switch
4
Alarm buzzer
2. Electrical connections for the various peripherals
Warning! Switch off the electric power supply to the control unit before connecting any
peripherals.
Refer to the general electrical diagram page 42.
a. Orange Warning Light
The Orange Warning Light must be connected in parallel with the integral lamp.
The Orange Warning Light will come on with a 2 sec warning every time the control unit is
operated. It will go out automatically after 2 minutes once the door stops.
b. Reflex Photo-electric Cells
Remove the link between T17 – T18.
Reference
9011084
9013647
1841028
1841036
9014397
35