Prestaciones En Refrigeración Unidad Estándar Neptuno M "A; Prestaciones En Calefacción Unidad Estándar Neptuno M "A - Ferroli NEPTUNO ECO-DUAL A Serie Manual Tecnico Del Instalador Y Del Usario
Prestaciones en refrigeración unidad estándar Neptuno M Bomba de Calor
MODELO
Tw
kWf
6
56.05
7
57.78
50A
8
59.52
9
60.96
10
62.40
6
66.45
7
68.51
60A
8
70.56
9
72.28
10
73.98
6
75.86
7
78.20
70A
8
80.54
9
82.50
10
84.46
6
88.25
7
90.98
90A
8
93.71
9
95.98
10
98.26
6
107.78
7
111.11
100A
8
114.44
9
117.22
10
120.00
6
123.41
7
127.22
125A
8
131.04
9
134.22
10
137.40
Prestaciones en calefacción unidad estándar Neptuno M Bomba de Calor
MODELO
-5
Tw
kWc
35
41.51
40
39.88
50A
45
37.73
50
36.62
35
47.94
40
46.06
60A
45
43.58
50
42.29
35
53.55
40
51.40
70A
45
48.60
50
47.30
35
70.22
40
67.47
90A
45
63.78
50
61.98
35
78.93
40
75.89
100A
45
71.74
50
69.72
35
96.20
40
92.41
125A
45
87.45
50
84.92
Tw = Temperatura salida agua en ºC
Las prestaciones estándar se refieren a una diferencia de 5ºC de temperatura entre la entrada y salida del intercambiador, y funcionando la unidad con todos los ventiladores
a la máxima velocidad. Se considera además un factor de ensuciamiento de 0.44 x 10
Datos técnicos y prestaciones
25
30
kWa
kWf
12.50
52.58
12.62
54.20
12.75
55.83
12.80
57.19
12.94
58.54
14.74
62.33
14.89
64.26
15.04
66.19
15.10
67.80
15.26
69.41
15.95
71.16
16.10
73.35
16.26
75.56
16.33
77.39
16.51
79.22
24.90
82.78
25.14
85.34
25.39
87.91
25.50
90.03
25.77
92.17
27.34
101.10
27.62
104.23
27.89
107.35
28.00
109.96
28.30
112.56
30.99
115.76
31.30
119.34
31.61
122.92
31.74
125.90
32.08
128.89
-2
kWa
kWc
kWa
12.67
46.91
12.99
14.42
44.77
14.58
16.10
43.14
16.18
17.45
40.99
17.53
14.05
54.18
14.40
15.99
51.70
16.17
17.84
49.82
17.93
19.35
47.34
19.43
16.65
60.45
17.03
19.02
57.65
19.11
21.10
55.60
21.29
22.99
52.80
23.09
24.88
79.30
25.54
28.50
75.61
28.61
31.68
72.87
31.90
34.42
69.27
34.53
24.88
89.15
25.53
28.42
85.10
28.61
31.68
81.97
31.87
34.38
77.91
34.57
30.53
108.65
31.31
34.96
103.69
35.15
38.90
99.90
39.09
42.25
94.94
42.34
kWf = Potencia frigorífica (kW)
TEMPERATURA AIRE EXTERIOR (ºC B.S.)
35
kWa
kWf
kWa
14.06
49.60
15.62
14.20
51.14
15.78
14.34
52.67
15.94
14.40
53.94
16.00
14.55
55.23
16.18
16.58
58.81
18.42
16.75
60.63
18.61
16.92
62.44
18.79
16.99
63.95
18.87
17.16
65.48
19.08
17.93
67.12
19.93
18.12
69.20
20.13
18.30
71.28
20.33
18.37
73.01
20.41
18.57
74.74
20.63
28.00
78.09
31.11
28.29
80.51
31.43
28.58
82.93
31.75
28.68
84.94
31.87
28.99
86.96
32.21
30.76
95.38
34.17
31.07
98.33
34.52
31.38
101.28
34.87
31.50
103.74
35.01
31.84
106.20
35.38
34.87
109.21
38.73
35.21
112.59
39.13
35.56
115.96
39.52
35.70
118.78
39.67
36.10
121.60
40.10
TEMPERATURA AIRE EXTERIOR (ºC B.H.)
2
kWc
kWa
kWc
49.31
13.07
55.06
48.54
14.58
54.46
48.20
16.26
53.86
47.77
17.53
52.83
56.95
14.49
63.59
56.06
16.17
62.90
55.66
18.02
62.20
55.17
19.43
61.01
63.62
17.13
70.99
62.50
19.21
70.15
62.22
21.38
69.50
61.57
23.09
68.10
83.37
25.65
93.12
82.04
28.83
92.08
81.57
32.01
91.13
80.72
34.64
89.33
93.76
25.72
104.71
92.28
28.79
103.52
91.73
32.05
102.50
90.81
34.57
100.48
114.29
31.51
127.62
112.44
35.35
126.16
111.76
39.29
124.89
110.69
42.44
122.37
kWc = Potencia calorífica (kW)
m