Voltage Test
Without activation of the two push buttons follow-
ing voltage steps are displayed: 24 V, 50 V, 120 V, 230
V, 400 V, 690 V (AC/DC).
By activation of the two push buttons (6 and 9) a lower
impedance is switched on. This can be used for the elimi-
nation of inductive and capacitive ghost voltages. Addi-
tional the LED's + 12 V and - 12 V will be active.
The duration of the test at lower impedance (load test)
depends on the measured voltage.
Due to limitation of internal temperature, the test time
will be limited automatically.
Observe safety measures. Connect both test probes to
test object.
• From a voltage of approx. 24 V the voltage tester
switches on automatically.
• The voltage is indicated by LED.
• For AC voltages the "+" and "-" LEDs are both illumi-
nated.
• The voltage tester has a LED row with the values 12 V,
24 V, 50 V, 120 V, 230 V, 400 V, 690 V.
• For DC voltage, the polarity of the voltage displayed
refers to the instrument test probe (2).
• By activation of the two push buttons the internal load
is switched on and the + 12 V / - 12 V LED will illuminate
additionally
22