Ariston AHVP 6.4F AL K Instrucciones De Uso página 20

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 28
CONTROLS
The hood is fitted with a control panel with aspiration speed selection control and
a light switch to control cooking area lights.
Model with SOFT-TOUCH control panel
AHVP 8.7F LT K
To select the functions of the hood, simply touch the commands:
a.
Button to increase suction speed (power):
b.
Button to decrease suction speed (power).
c.
Button ON/OFF hood
d.
Button ON/OFF lighting
e.
Button ON/OFF programmed switching off:
it programs switching off of the active suction speed (power) after
approximately 3 minutes.
Models with Soft Button panel + LCD Display
AHVP 6.4F AL K
1.
OFF / Extraction speed (power) decrease button
2.
ON / Extraction speed (power) increase button
Note: The intensive extraction speed (power) is timed and lasts for 5
minutes (indicator c flashes); the hood then reverts to extraction speed
(power) 2.
3.
ON/OFF Timer button: delays the deactivation of the selected extraction
speed (power) by 5 minutes.
Note: the button is also used for the "Filter saturation signal reset" function
4.
Light ON/OFF button
5.
Display, shows:
a.
Extraction speed (power): the indicator rotates according to the
selected extraction speed (power).
Safety operation: the indicator flashes.
b.
Grease filter saturation: comes on when filter maintenance is
required.
c.
Timer
d.
Active carbon filter saturation: comes on when filter maintenance is
required.
Note: this function is normally disabled and should only be activated if
the hood is used as a filter version (with carbon filter fitted).
To do so, proceed as follows:
- switch off the hood
- press and hold buttons 1 and 3 at the same time, until the indicator
stops flashing (indicator disabled) and is lit steadily (indicator enabled).
- release the buttons.
To deactivate it, repeat the procedure: the indicator will no longer be lit
steadily (indicator enabled) and will flash instead (indicator disabled).).
e. Lighting
Safety operation
The hood has a sensor which, in the event of a sudden increase in temperature,
activates the appliance until the temperature drops significantly.
Filter saturation signal reset
After carrying out filter maintenance, press and hold button 3 until indicator.