Hold coupling nut and regulator
as shown for proper connection
to LP tank valve.
Leak Testing Valves, Hose and Regulator
1.Turnall grill control knobs to OFF.
2.Be sure regulator is tightly connected to LPtank.
3.Compieteiy
open LP tank valve by turning OPD hand wheel
counterclockwise.
If you hear a rushing sound, turn gas off
immediately.
There is a major Ieak at the connection.
Correct
before proceeding
by calling Sears for replacement
parts at
1-800-4-MY-HOME
_.
4.Brush soapy solution onto areas where bubbles are shown in
picture below:
6. Turn the coupling nut clockwise and tighten to a fuII stop. The
regulator wiII seat on the back-check
feature in the LPtank
valve, resulting in some resistance. An additional one-half to
three-quarters
turn is required to complete the connection.
Tighten by hand only - do not use tools.
NOTE"
If
you
cannot
complete
the
connection,
disconnect
regulator
and repeat steps 5 and 6. If you are still unable to complete the
connection, do not use this regulator!
Catt 1-800-4-MY-HOME
® for an identical replacement part.
•
Never remove
threaded
orifice at end of valve.
• Do not insert any tool or foreign object into the valve
outlet or safety relief valve. You may damage the valve
and cause a leak. Leaking propane may result in
explosion, fire, severe personal injury, or death.
• Outdoor gas appliance is not intended to be installed
in or on a boat.
• Outdoor gas appliance is not intended to be installed
in or on an RV.
• Never attempt to attach this grill to the self-contained
LPgas system of a camper trailer or motor home.
• Do not use grill until leak-tested.
• If a leak is detected at any time, STOP and call the fire
department.
• If you cannot stop a gas leak, immediately close
LP cylinder
valve and call LP gas supplier
or your fire
department!
6 ° 16132-40200139
5. If "growing"
bubbles appear, there is a leak. Close LPtank
valve immediately and retighten connections. If leaks cannot be
stopped do not try to repair. Catt Sears for replacement
parts at 1-800-4-MY-HOME
®.
6. Aiways ciose LPtank valve after performing teak test by
turning hand wheel clockwise.