Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 36
SPECIFICATION
Power Supply:
Sensitivity Levels:
Standby Current:
Alarm Current:
Alarm:
Normal Sensor Life:
Certification:
DISPOSAL
Please ensure the unit is disposed of in accordance with local regulations, once
it has come to the end of its life.
WHEN HOUSEHOLD CLEANING SUPPLIES OR SIMILAR CONTAMINATES ARE
USED, THE AREA MUST BE WELL VENTILATED.
THE FOLLOWING SUBSTANCES CAN AFFECT THE CO SENSOR AND MAY
CAUSE FALSE ALARMS AND DAMAGE TO THE SENSOR:
METHANE, PROPANE, ISO-BUTANE, ISO-PROPANOL, ETHYL ACETATE,
HYDROGEN SULFIDE DIOXIDES, AND ALCOHOL BASED PRODUCTS, PAINTS,
THINNERS, SOLVENTS, ADHESIVES, HAIR SPRAY, AFTER SHAVE, PERFUME,
AND SOME OTHER CLEANING AGENTS.
Please see reverse for further instructions.

USING THE ALARM

The unit will sound "Beep" and the Red LED will flash once as a power up. The
unit will start to detect CO within 90 seconds of the batteries being installed.
Normal Conditions:
If there is no CO present, the green power LED will flash once every 30 seconds.
Alarm Conditions:
If the unit detects CO the alarm pattern will sound (3 short beeps) and the Red
LED will flash for as long the CO remains at a dangerous level.
Silence Function:
If required, the audible alarm can be silenced by pressing the "Test" button. The
alarm will re-activate after 30 seconds if CO remains present.
DC 9 V battery
50 ppm between 60 and 90 mins
100 ppm between 10 and 40 mins
300 ppm within 3 mins
< 50 μA
< 50 mA
Loud 85 decibel audible alarm and flashing Red LED
indicator
6 Years
EN50291:2001
3
ENGLISH

Publicidad

Tabla de contenido
loading

Tabla de contenido