9. USER SETTINGS MENU
Pressing the "STOP / ESC" button switches to the main menu for
entering user data. These settings are global, and not specific to
any particular memory.
(user setup)
Language
: English
Rest Time
: 2 min
Safety Cut
: OFF
Safety Time
: 1 min
Capa Ct
: OFF
Capa value
: 100 mAh
Key Beep
: ON
(user setting)
Buzzer
: ON
Input Low
: 10.5 V
Int. Temp.
: 39°C
Reset
: Reset
Version
: V1.00
Menu language selection: English,
Language
German, Italian and French
Pause setting between two cycles (1 - 60 min.).
This setting is only useful when charging NiCd /
Pause
NiMH batteries.
If this function is active (ON), the process you
have started is interrupted when the set "time
limit" has elapsed, or when another cut-off
Time cut-off
parameter is triggered, such as Delta-Peak,
final discharge voltage, etc. A corresponding
message is displayed.
Time setting after which the process is stopped
Time limit
automatically. Adjustment range: Off - 720 min.
If this function is active (ON), the process you
have started is interrupted when the set "capa-
Capacity cut-
city limit" is reached, or when another cut-off
off
parameter is triggered, such as Delta-Peak,
final discharge voltage, etc. A corresponding
message is displayed.
Capacity setting after which a process is auto-
matically stopped. Adjustment range: 0.1 - 60
Capacity limit
Ah
Switch button beep on and off.
Button beep
Switch melody on and off. The melody sounds
Buzzer
when a process is concluded, or to alert you to
an error.
At this point you can define the input level which
triggers a low-voltage alarm, e.g. in order to
protect a car battery used as power source
Low voltage
from becoming deep-discharged. Adjustment
range: 10.3 V - 11.0 V, variable in 0.1 V incre-
ments.
Displays the internal temperature of the charger.
Int. temp
Selecting this point erases all the previously set
parameters, and restores them to the factory
Reset
default values. This is achieved by holding the
"START / ENT." button pressed in for at least
two seconds.
Display of charger firmware version.
Version
Operating Instructions
Power Peak E7 EQ-BID
®
10. CYCLE DATA MENU
If no charge or discharge process is active, pressing the "STOP
/ ESC" button switches to the menu for viewing the cycle data.
Here you can view all the data relating to a charge or discharge
process.
The battery capacity is displayed both in the Charge (C:) line and
the Discharge (D:) line. The "C" line also displays the highest
voltage of the battery while the "D" line shows the lowest battery
voltage.
Press the "+" or "-" button to view all the data of a cycle (max. ten).
Note:
To erase the data, switch the charger off, or define a new battery.
11. MODE SELECT (CHARGE / DISCHARGE / CYCLE)
Once all the charge / discharge parameters have been set, the
charge or discharge mode can be selected: hold the "START /
ENT." button pressed in for at least two seconds in the "Memory
name" menu. The screen display now changes, and you see a
menu for selecting the mode. The top line displays the essential
battery data. In the lower part of the upper screen you can set the
desired process.
To make a selection you must press the "+" or "-" button. To start
the process press the "START / ENT." button briefly. The following
charge processes are available for NiCd and NiMH batteries:
• Charge
• Automatic
• Discharge
• Re-peak
• Cycle
The following charge processes are available for Lithium and Lead
batteries:
• Charge
• Discharge
• Storage
• Fast-charge
• Balance
(01) Memory name. .
NiMH
Cycle mode:
Cycle
• C>D (charge / discharge) • D>C (discharge / charge)
24
10
Cycle data
No.
Capacity
Voltage
1 C:
0 mAh
11.358 V
D:
0 mAh
0.000 V
2 C:
0 mAh
11.412 V
D:
0 mAh
0.000 V
3 C:
0 mAh
0.000 V
D:
0 mAh
0.000 V
6-cell
2000 mAh
D>C
:
1
# 30 8127
The
example
alongside
shows
the "CYCLE" pro-
cess; at this point
you can determine
the
sequence
of
the cycle, and the
number of cycles.