1.5. INSTALLATION CONDITIONS
2. DESIGN
2.1. MATERIAL
INFO:
The housing consists of high
grade sheet steel (St 1203),
t=1.25 mm, and is powder-
coated
2.2. ACCESSORIES
Activated carbon fi lter (3,500 g) incl. suspended solids preliminary fi lter.
3. MODE OF OPERATION
3.1. FUNCTION
CAUTION:
Installation may only take place in a non-ex-zone!
The extraction air is cleaned to 99.999 % of hydrocarbons by the integrated activated carbon fi lter so
that it can be directly given o to the ambient air. The extraction air fl ow containing pollutants does
not come into contact with energised components. Hence the appliance is suitable for suctioning out
cabinets defi ned in EN 14470 Part 1 rsp. DIN 12925 Part 1. There is thus no need for an extraction air
line leading to a safe place outdoors.
A CE conformity attestation (also in acc. with EC directive 94/9/EC - ATEX directive) is on hand.
RAL
7035
RAL
7016
fresh air
CAUTION:
Filter can only retain
ventilator
solvent vapours
activated carbon filter
(hydrocarbons). Please
consult us if other
materials are to be
stored.
Safe and faultless
function is shown by the
ventilation and filter
monitoring mechanism
which is fitted as
standard. (3.2)
gases and vapours in cabinet
EN
9
9