INDICATOR
Green "ON"
Yellow "Boost / Absorption"
Yellow "Floating"
These indicators are visible from the front of the appliance through the light guides, thereby allowing
operation of the appliance to be monitored.
4.
EQUIPMENT MAINTENANCE AND REPAIRS
4.1.
O
VERVIEW
This paragraph deals with equipment maintenance and repairs. Proper operation of the product and its
service life are dependent on strict compliance with the following recommendations.
4.2.
E
QUIPMENT MAINTENANCE
Disconnect the battery charger from the AC network before starting any maintenance work.
If appliances are in a dusty atmosphere, vacuum-clean them regularly, since dust deposits may adversely
affect heat release.
Check the state of battery charge every 3 months.
The tightness of nuts and screws should be checked annually to ensure efficient operation of the appliance
(particularly in hostile conditions: vibrations, shocks, high variations in temperature etc.).
A full technical inspection by a CRISTEC-accredited engineer is recommended every five years. It can also
be done at our plant.
4.3.
E
QUIPMENT REPAIRS
Disconnect the battery charger from the AC power network and disconnect the batteries before undertaking
any repairs.
When fuses have blown, only use fuses of the type and size recommended in this manual.
Please contact a reseller or CRISTEC for any other repairs.
STATE
On
Off
On
Flashing
Off
On
Off
CPS3OEM-24V-60A-115VAC-DEC
MEANING
- Charger is ON
- No or poor quality AC current
or
- Input fuse blown
or
- Internal charger malfunction
- SW1 Switch:
Boost in OFF position
- SW1 switch:
or
Boost in ON position and Boost/Absorption
phase completed
- SW1 Switch:
Boost in ON position and charger in the
Boost/Absorption phase
- Internal charger malfunction
or
- Output fuse blown
Charger current < 20% rated current (floating
phase)
Charger current > 20% rated current
26