− The charger identifi es the modes matching the battery type. Therefore, not every
mode can be selected for each battery.
− Once a mode has been selected, it will begin charging. If a battery remains
connected to the charger after it has been completely recharged, the charger
automatically switches to trickle charging. The battery continues to be trickle
charged even if a different mode is selected.

Status displays

If the charger has been switched on, the background illumination is blue.
During the charging operation, the selected charging mode, the current battery
voltage and the charging status of the battery are displayed.
In case of faulty operation (e.g. resulting from overheating or electric short circuit),
fault symbols are displayed, and the appliance switches to stand-by mode if
necessary.
LED
6 V / 0.8 A
Charging operation for 6 V battery
Recommended battery capacity 1.2 to 14 Ah, charging current 0.8 A and 3.8
A
12 V / 0.8 A
Charging operation for 12 V motorcycle battery or 12 V motor vehicle battery
Recommended battery capacity 1.2 to 120 Ah, 0.8 A charging current
12 V / 3.8 A
Rapid charging operation for 12 V motor vehicle battery
Recommended battery capacity 1.2 to 120 Ah, 3.8 A charging current
12 V / 3.8 A COLD
at low ambient temperature only for 12 V battery
Recommended battery capacity 1.2 to 120 Ah, 3.8 A charging current
Charging status: Battery symbol outline fl ashing, 1 to 5 bars are displayed:
Charging operation active
/
Charging status: 5 bars are displayed, frame is illuminated continuously:
The battery is fully charged.
Trickle charging with fully charged battery.
Fault: Battery faulty
Fault: incorrectly connected terminals
Fault: no battery connected, short circuit
standard charging mode:
standard charging mode:
rapid charging mode:
rapid charging mode: Rapid charging operation