MANUAL OPERATION (COOL, DRY, HEAT/FAN)
1
To select the COOL, DRY or HEAT/FAN mode:
Press the
2
˚C
CLOCK
Select the operation mode by pressing the
AMPM
Each time this button is pressed, the operation mode is changed in sequence:
AMPM
(I FEEL...) →
TOO
TOO
ON/OFF
WARM
COOL
HEAT mode or FAN mode
Check the type of the air conditioner. (Refer to page 4.)
FAN
STOP
COOL & HEAT
I FEEL COOL
VANE
START
COOL ONLY
HEAT
DRY
MODE
WIDE VANE
HR.
To stop operation:
ECONO COOL
LONG
MIN.
I
Press the
RESET CLOCK
After the operation mode is set once, the operation starts in the same mode as
the one set previously from the next time by simply pressing the
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
I
When the set temperature is to be changed:
TOO
WARM
• Press the
button to lower the temperature. One press lowers the temperature by about 1°C.
TOO
COOL
• Press the
button to raise the temperature. One press raises the temperature by about 1°C.
In HEAT operation
• If the air conditioner absorbs too much heat from the air, it may be overloaded. Following a judgement made by the
microprocessor, the fan in the outdoor unit is automatically stopped to protect the air conditioner.
When the outdoor unit's fan is stopped, frost may form on the outdoor unit, but this is not a problem.
In DRY operation
• The temperature control (temperature setting) cannot be done.
• The room temperature is slightly lowered in this operation mode.
I
The details of the display on the indoor unit are explained on page 6.
NOTE:
When the ambient temperature is too high, the room temperature may not reach the set temperature since the unit
operates to cool the room under a high load.
Information for multi system air conditioner (Outdoor unit: MXZ series)
Multi system air conditioner (Outdoor unit: MXZ series) can connect two or more indoor units with one outdoor
unit. According to the capacity, two or more units can operate simultaneously.
• When you try to operate two or more indoor units with one outdoor unit simultaneously, one for the cooling and the other
for heating, the operation mode of the indoor unit that operates earlier is selected. The other indoor units that will start the
operation later cannot operate, indicating an operation state. (Refer to the table of Operation Indicator lamp on page 6.)
In this case, please set all the indoor units to the same operation mode.
• When indoor unit starts the operation while the defrosting of outdoor unit is being done, it takes a few minutes (max. 10
minutes) to blow out the warm air.
• In the heating operation, the indoor unit that does not operate may get warm or the sound of refrigerant flowing may be
heard. This is not a malfunction since the refrigerant continuously flows into the indoor unit that does not operate.
Description of "AUTO RESTART FUNCTION"
Refer to page 6.
ON/OFF
button.
MODE
button.
(COOL) → (DRY) →
(HEAT: MSH series)/
Type
Operation mode
HEAT
FAN
ON/OFF
button.
AIR FLOW VELOCITY AND DIRECTION ADJUSTMENT
AIR FLOW velocity and direction can be selected as required.
˚C
CLOCK
(FAN: MS series)
AMPM
AMPM
TOO
TOO
ON/OFF
WARM
COOL
FAN
STOP
I FEEL COOL
VANE
START
HEAT
DRY
MODE
WIDE VANE
HR.
ECONO COOL
LONG
MIN.
ON/OFF
button.
RESET CLOCK
NOTE:
• In the cooling operation, when the air conditioner is operated with setting the horizontal vane to
1 hour, the AIR FLOW direction is automatically set to horizontal to prevent condensed water from dropping.
• Adjust the vertical AIR FLOW direction using the remote controller. If the horizontal vane is moved manually, it may
cause trouble.
• In the heating operation, if the air flow temperature is too low or when defrosting is being done, the horizontal vane
position is set to
(1).
Auto air flow direction control operation
When the AUTO mode is selected with the
correspond to the operation mode for effective operation.
(1) HEAT:
When the air flow temperature is too low, the air is blown out horizontally.
When the air flow temperature rises, the air is blown out downwards.
(2) COOL, DRY: The air is blown out horizontally.
(3) FAN:
The air is blown out downwards.
I
To change the AIR FLOW blowing direction horizontally, press the
Each time the button is pressed, the angle of the VERTICAL VANE is changed in sequence:
→
→
SWING OPERATION
Use the swing operation for the air flow to reach all corners of the room.
Horizontal AIR FLOW blowing range
COOL/DRY
About 100°
HEAT
About 150°
I
To change the AIR FLOW velocity, press the
Each time the button is pressed, the fan speed is changed in sequence:
(Low) →
(Med.) →
(High) →
• Use the
(High) notch to cool/heat the room more.
• If the operating sound of the air conditioner disturbs your sleep, use the
(Low) notch.
I
To change the AIR FLOW blowing direction vertically, press the
VANE
button.
Each time the button is pressed, the angle of the horizontal vane is changed in
(1) →
(2) →
(3) →
sequence:
SWING OPERATION
Use the swing operation for the air flow to reach all corners of the room.
Recommended horizontal vane range
Use the
(AUTO) position usually.
Use position
(1) or
(2) in the COOL or DRY mode
and use positions
(3) to
(5) in the HEAT mode
when adjusting to your requirements.
VANE
button, the position of the horizontal vane is automatically set to
→
→
(SWING) →
→
NOTE:
Adjust the horizontal AIR FLOW direction using the
remote controller. If the VERTICAL VANE is moved manu-
ally, it may cause trouble.
FAN
button.
(AUTO)
(4) →
(5) → (SWING) →
(AUTO)
1
COOL
2
DRY
3
HEAT
4
5
(4) or
(5) for
WIDE VANE
button.
7