6. Turn operating switch I (10) on the station to position 0 and move the steam
regulator (9) to MIN. Please ensure that operating switch II (11) is turned to
position I. Operating switch II (11) lights up.
7. The control lamp of the iron (5) shows it is being heated up. As soon as the
control lamp goes off the operating temperature has been reached. Now you
can start ironing.
8. Always remove the mains plug after using the machine.
Steam Ironing
For this a high temperature is needed.
1 . Turn the temperature control (1) to position „• • •" (cotton, linen).
2 . Move both operating switches (10/11) to position I. During operation the control
lamp (12) shows whether there is enough steam available for steam operation.
On = enough steam available,
Off = steam being produced
Warning: The steam is hot! There is a danger of scalding!
3. You can set the desired quantity of steam with the steam regulator (9).
4. With the steam jet button (2) you can produce a short strong jet of steam.
Continuous steam is produced by locking the catch (3) in place.
Filling in Water during Operation
1. The control lamp (13) lights up when the water tank is empty.
2. The water tank can be replenished with water. First turn operating switch I (10)
to 0. Operating switch II (11) remains switched to I.
Note: If there is still some residual pressure in the water tank, a safety lock
prevents the water tank catch (7) from being opened. The residual pressure
fi rst has to be relieved before the device can be safely opened.
3. With the steam jet button you can now release the residual steam pressure.
When no further steam comes out of the iron sole plate, turn operating switch
II (11) to 0. Then please remove the mains plug and carefully open the water
tank lock (7).
Warning: The steam is hot! There is a danger of scalding!
4. With the help of a funnel fi ll freshwater from a measuring beaker into the water
tank. Do not overfi ll! Take care of water splashes that might come out of the
boiler. In order to prevent the water from splashing it should be fi lled into the
funnel slowly after the safety lock has been opened.
5. Fasten the safety lock again.
6. Insert the power plug back into the socket.