TROUBLESHOOTING
The following symptoms do not indicate malfunction.
The following symptoms do not indicate malfunction.
SYMPTOM
SYMPTOM
Mist emerges from indoor unit.
Water fl owing sound during operation.
The room has a peculiar odour.
Indoor fan stops occasionally during automatic fan speed
setting.
Operation is delayed a few minutes after restart.
Outdoor unit emits water/steam.
Timer indicator is always on.
Cracking sound during operation.
Inconsistent airfl ow during PATROL operation.
Check the following before calling for servicing.
Check the following before calling for servicing.
SYMPTOM
SYMPTOM
Cooling operation is not working effi ciently.
Noisy during operation.
Remote control does not work.
(Display is dim or transmission signal is weak.)
The unit does not work.
The unit does not receive the signal from the remote
control.
Patrol sensor or e-ion indicator on the indoor unit is
blinking.
Notes on "ECO PATROL SENSOR"
Notes on "ECO PATROL SENSOR"
• Sensor may not detect moving objects further than 7m away or beyond detection angle.
• Sensor sensitivity is infl uenced by indoor unit location, movement speed, temperature range, etc.
• The sensor may mistakenly detects pets, sunlight, certain lighting, fl uttering curtains and light refl ection as human being.
► • Condensation effect due to cooling process.
► • Refrigerant fl ow inside the unit.
► • This may be due to damp smell emitted by the wall,
carpet, furniture or clothing.
► • This helps to remove the surrounding odours.
► • The delay is a protection to the unit's compressor.
► • Condensation or evaporation occurs on pipes.
► • The timer setting repeats daily once set.
► • Changes of temperature cause the expansion/
contraction of the unit.
► • Fan speed is adjusted automatically during patrol
operation.
Select QUIET operation to maintain the airfl ow
consistency.
► • Set the temperature correctly.
• Close all doors and windows.
• Clean or replace the fi lters.
• Clear any obstruction at the air inlet and air outlet vents.
► • Check if the unit has been installed at an incline.
• Close the front panel properly.
► • Insert the batteries correctly.
• Replace weak batteries.
► • Check if the circuit breaker is tripped.
• Check if timers have been set.
► • Make sure the receiver not obstructed.
• Certain fl uorescent lights may interfere with signal
transmitter. Please consult authorized dealer.
► • Stop Patrol or e-ion operation then restart. If the patrol
sensor or e-ion indicator still blinking, please consult
authorized dealer.
CAUSE
CAUSE
CHECK
CHECK
7