Cleaning And Maintenance - Fiap AIR ACTIVE OxyFlow Instrucciones De Uso

Ocultar thumbs Ver también para AIR ACTIVE OxyFlow:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 20
POND AERATION
AIR ACTIVE OxyFlow
The device is delivered with LED lighting. To remove the lighting, turn the light with one of
the three edges on the transparent cover until it is flush with the small gap on the float
and carefully push the light down and out of the float (light pressure must be sufficient,
do not use force! Under certain circumstances it may be necessary to move the parts
of the float a little, this makes it easier to install and remove the lights). If not all lights
are pre-assembled, first check whether all sealing caps are screwed on. Carefully insert
the lights one after the other from bottom to top into the openings provided in the float
(also note the position of the edges in the lid). Then mount the pump housing with the
pump on the float. To do this, insert the housing with the pump rotor up into the float.
Secure the pump housing with the three long retaining pins (screws). Connect the cable
of the pump motor with the connector of the control. Put the assembled aerator in its
intended position in the pool and fix it with the supplied cord. It is important that the
aerator is secured on at least two opposite sides. Finally, connect the lighting lead to the
transformer supplied. As soon as all preparations have been made and the aerator is
immersed in the pool, it can be put into operation.
Watch the aerator running for about 30 minutes and check for unusual noises and stea-
dy flow of water. If the aerator does not run properly for more than 30 minutes, there
is a fault and must be remedied.
IMPORTANT: The pump motor can be varied by controlling from level 0 - 100 using the
triangular buttons. After releasing the button, the control shows the current power
consumption (watt). The last set power level is retained even after disconnection from
the power supply. Operation via a timer is therefore possible without any problems.

CLEANING AND MAINTENANCE

Before cleaning and servicing, ensure that the device is switched off and unplugged from
the power source.
The filter housing and the impeller must be cleaned at regular intervals. The cleaning
interval depends heavily on the degree of soiling. The degree of pollution can vary sig-
nificantly from water to water. To clean the housing and the motor, first remove the
ventilator float (loosen the three long retaining pins). Open the filter basket by turning
the basket counterclockwise. To clean the rotor and the internal parts, also remove the
corresponding screws. The rotor can then easily be pulled out of the liner and cleaned.
Do not use any sharp-edged objects such as Steel brushes, use a soft sponge instead.
Stubborn dirt such as Limescale deposits are best removed with premiumcare PUMP
10
CLEANSER pump cleaner. If there is sufficient flow, the pump is cooled by the water.
Always make sure that the pump works against as little resistance as possible. If the
Observe the relevant product videos on the subject of
installation and commissioning
in our Youtube channel:
https://www.youtube.com/user/FIAPGmbH
GB

Publicidad

Tabla de contenido
loading

Tabla de contenido