WARNING
After fueling, tighten down the filler cap
by hand as securely as possible.
BT 130
Auger Brake
Activating the auger brake
A
Set the activating lever to A
N
when starting
–
when idling
–
to unscrew a secured auger
–
If the auger catches in the drilled hole
(e. g. on roots or stones), the auger
moves counterclockwise – the activating
lever is pushed against the thigh of the
operator and the auger brake is
triggered.
Releasing the auger brake
B
Set the activating lever to B
N
Checking the auger brake for proper
functioning
The auger brake is subject to normal
wear. Before starting work and after
releasing a jammed auger, check
regularly if it is fulfilling its function.
Each time before starting work and after
releasing a jammed auger
When idling, activate the auger
N
brake and open the throttle wide for
a brief period (max. 3 seconds) –
the auger must not rotate.
If the auger brake fails, it must be
repaired immediately by a servicing
dealer – STIHL recommends the STIHL
dealer.
English
13