Base Grille Water Filtration System
Model WF-LC400V/LC400V
Capacity
400 Gallons
(1514 Liters)
Tested and certified by NSF IntemaSonal against ANSI/NSF
Standard
42 for the reduction of Chlorine, Taste and Odor, Particulate Class I*;
and against ANSI/NSF Standard 53 for the reduction of Lead,
Mercury, Atrazine, Benzene, Toxaphene, p-dichlorobenzene,
2, 4-D,
Cysts, Turbidity and Asbestos.
This system
has been tested
according
to ANSI/NSF
42/53
for the reduction
of the substances
listed
below.
The concentration
of
the indicated
substances
in water
entering
the system
was reduced
to a concentration
less than
or equal
to the permissible
limit for
water
leaving
the system,
as specified
in ANSI/NSF
42/53.
Substance
Reduction
NSF
Average
Influent Challenge
Maximum
Average
Minimum %
Average % NSF Test
Aesthetic Effects
Reduction
tnfluent
Concentration
Effluent
Effluent
Reduction
Reduction
Number
Requirements
Chlorine Taste/Odor
->50%
2.1 mg/L
2.0 mg/L ± 10%
0.06 mg/L
0.05 mg/L
97.1%
97.6%
507!73-02
Particulate Class 1"
->85%
5,366.667/mL
Atpartleastc
es/m10'000L
4,100/mL**
2,3OO/mL
99.3%
99.9%
507175-02
Contaminant
NSF
Average
Influent
Challenge
Maximum
Average
Minimum %
Average % NSP Test
Reduction
Reduction
tnfluent
Concentration
Effluent
Effluent
Reduction
Reduction
Number
Requirements
Lead: @ pH 6.5
0.01mg/L
0.16 mg/L***
0.15 mg/L ± 10%
0.001 mg/L
0.001 mg/L
99.3%
99.35%
507601-01
Lead: @ pH 8.5
0.01mg/L
0.15 mg/L***
0.15 mg/L ± 10%
0.001 mg/L
0.001 mg/L
99.2%
99.31%
507602-01
Mercury: @ pH 6.5
0.002 mg/L
0.0061 mg/L
0.006 mg/L ± 10%
0.0004 mg/L
0.0003 mg/L
93.5%
96.7%
507603-02
Mercury: @ pH 8.5
0.002 mg/L
0.0057 mg/L
0.006 mg/L ± 10%
0.0008 mg/L
0.00051 mg/L
85.8%
91.2%
507604-02
Benzene
0.005 mg/L
0.0138 mg/L
0.015 ± 10%
0.0005 mg/L
0.005 mg/L
96.3%
96.3%
507183-02
p-dichlorobenzene
0.075 mg/L
0.220 mg/L
0.225 ± 10%
0.0005 mg/L
0.0005 mg/L
99.7%
99.7%
507186-02
Toxaphene
0.003 mg/L
0.014 mg/L
0.015 ± 10%
0.0014 mg/L
0.001 mg/L
90%
92.96%
507185-02
Atrazine
0.003 mg/L
0.009 mg/L
0.009 mg/L ± 10%
0.0013 mg/L
0.00036 mg/L
85.6%
85.6%
507181-02
2, 4-D
0.07 mg/L
0.197 mg/L
0.215 ± 10%
0.058 mg/L
0.0137 mg/L
70.6%
93.06%
507180-02
Asbestos
99%
26 x 10
10to
108fibers/L **** 0.18 x 10 mg/l
0.18 x 10 _ mg/L
99.93
99.93%
507178-02
Cysts .....
99.95%
111,000/mL
50,000/L rain.
1 mg/L
mg/L
99.99%
99.99%
507187-02
Turbidity
0.5 NTU
11.08 NTU
11 ± 1 NTU
0.13 NTU
0.078 NTU
98.8%
99.3%
507751-02
Test Parameters: pH = 7.5 _+0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 63°F
(17.2°C).
It is essential that operational, maintenance, and filter
replacement
requirements be carried out for the product to
perform as advertised.
Model WF-LC400V
The filter monitor system measures the
amount of water that passes through the filter and alerts you
to replace the filter. When 90% of the filter's rated life is used,
the filter indicator light changes from green to yellow. When
100% of the filter's rated life is used, the filter indicator light
changes from yellow to red, and it is recommended
that you
replace the filter. Use replacement cartridge LC400V, part
#9908. 2003 suggested retail price of $39.95 U.S.A./S49.95
Canada. Prices are subject to change without notice.
The product is for cold water use only.
Do not use with water that is microbiologically
unsafe or of
unknown quality without adequate disinfection
before or after
the system. Systems certified for cyst reduction may be used
on disinfected
waters that may contain filterable cysts.
Refer to the front
cover
or "Accessories"
section
for the
Manufacturer's
name,
address
and telephone
number.
Refer to the "Warranty"
section
for the Manufacturer's
limited
warranty.
Application
Guidelines/Water
Supply
Parameters
Water Supply
City or Well
Water
Pressure
30 - 120 psi (207 - 827 kPa)
Water Temperature
33 ° - 100°F (0.6 ° - 37.8 ° C)
Service
Flow Rate
0.5 GPM (1.89 L/rain.)
@ 60 psi.
*Class I particle size: >0.5 to <1 um
**Test requirement is at least 100,000 particles/mL
of AC Fine Test Dust.
***These contaminants
are not necessarily in your water supply, Performance
may vary based on Ioca( water conditions.
.... Fibers greater than 10 um in length
*****Based
on the use of Cryptosporidium
parvum oocysts
® NSF is a registered trademark
of NSF International.